SUPER-DAQ Precision Temperature Scanner
General Specifications
5
General Specifications
Mains Voltage
100 V Setting ...................................................... 90 V to 110 V
120 V Setting ...................................................... 108 V to 132 V
220 V Setting ...................................................... 198 V to 242 V
240 V Setting ...................................................... 216 V to 264 V
Frequency
.............................................................. 47 Hz to 440 Hz
Power
Consumption
............................................. 36 VA peak (24 W average)
Environment Temperature
Operating ............................................................ 0 °C to 50 °C
Full accuracy ....................................................... 18 °C to 28 °C
Storage ...............................................................
−
20 °C to 70 °C
Warm-up ............................................................. 1 hour to full accuracy specifications
Relative Humidity (non-condensing)
Operating ............................................................ 0 °C to 30 °C <80 %
30 °C to 50 °C <50 %
Storage ...............................................................
−
20 °C to 70 °C <95 %
Altitude
Operating ............................................................ 2,000 m
Storage ............................................................... 12,000 m
Vibration and Shock
............................................. Complies with MIL-PRF-28800F Class 3
Channel Capacity
Total analog channels ........................................ 45
Voltage/resistance channels ............................... 41
Current channels ................................................ 5
Digital I/O ............................................................ 8 bits
Totalizer .............................................................. 1
Alarm outputs...................................................... 6
Trigger input ........................................................ 1
Safety
Mains Input ......................................................... IEC 61010-1, Overvoltage Category II, Pollution Degree 2
Measurement Input ............................................. 50 Vdc max, all functions and ranges.
Electromagnetic Environment
............................. IEC 61326-1: Basic (Controlled EM for full specification)
Radio Frequency Emissions
................................ IEC CISPR 11: Group 1, Class A. (Group 1 has intentionally generated
and/or uses conductively coupled radio-frequency energy which is
necessary for the internal functioning of the equipment itself. Class A
equipment is suitable for use in non-domestic locations and/or directly
connected to a low-voltage power supply network.)
Electromagnetic Compatibility
............................ Applies to use in Korea only. Class A Equipment (Industrial
Broadcasting & Communication Equipment)
[1]
[1] This product meets requirements for industrial (Class A)
electromagnetic wave equipment and the seller or user should take
notice of it. This equipment is intended for use in business
environments and is not to be used in homes.
Math Channels
Number of channels............................................ 20
Operations .......................................................... sum, difference, multiply, divide, polynomial, power, square root,
reciprocal, exponential, logarithm, absolute value, average, maximum,
minimum
Triggers
.................................................................. interval, external (trigger input), alarm, remote (bus), manual,
automated test
Memory
Scan data RAM................................................... 75,000 readings with timestamp
Data/Setup flash memory ................................... 20 MB