Set the connection on your computer as follows:
Bits per seconds:
9600 Bits
Data bits:
8
Parity:
none
Stop bits:
1
Flow control:
Hardware or
none
3.2.3.
Procedure
Connect the CCM 01 to an external computer (RS232 or Bluetooth)
Select „
MEASURE
“ in the main menu of the CCM 01 and confirm.
Start the measuring mode with „
START
“.
Stored data is provided periodically to the RS232
– interface or the Bluetooth EBT 01.
The cycle can be cancelled using [ESC] after the data transfer is done.
3.2.4.
Protocol for the contiuous data transfer
Generally the data telegrams are developed as follows:
$cmd(#par#par)*
$
marks the beginning of the data telegrams
cmd command
#
separator
par
parameter for the command
For more information: