FP6000 AND FP6100 SERIES

SWIMMING POOL PUMPS

To avoid unneeded service calls, prevent possible injuries, and
get the most out of your pump and filter, READ THIS MANUAL
CAREFULLY!

The Flotec FP6000 series self-priming centrifugal pump is
designed to be used as a filtration or circulation system pump
for in-ground swimming pools, spas, hot tubs, and solar sys-
tems.

The Flotec FP6100 series pump is designed to used as a filtra-
tion or circulation system pump for above ground swimming
pools, spas, hot tubs, and solar systems.

All models:

• Are designed to eliminate corrosion of parts under normal

pool usage and maintenance.

• Are excellent performers; durable, reliable, with non-clogging

impeller.

For other applications of pump, consult manufacturer.

TABLE OF CONTENTS

Safety Instructions......................................................................2

Installation ..................................................................................3

Electrical.....................................................................................4

Operation ...................................................................................5

Troubleshooting Guide ...............................................................5

Repair Parts List......................................................................6,7

Warranty.....................................................................................8

GENERAL

Pump has been carefully assembled, tested, inspected and
packed at our factory. Note any damage to product on delivery
ticket and file claim promptly with carrier or store of purchase.

READ AND FOLLOW ALL 
INSTRUCTIONS!

This is the safety alert symbol. When you see this symbol on your

system or in this manual, look for one of the following signal words

and be alert to the potential for personal injury.

warns about hazards that will cause death, serious personal

injury, or major property damage if ignored.

warns about hazards that can cause death, serious personal

injury, or major property damage if ignored.

warns about hazards that will or can cause minor personal

injury or property damage if ignored.

NOTICE indicates special instructions not related to hazards.

Carefully read and follow all safety instructions in this manual and on
equipment. 
Keep safety labels in good condition; replace if missing or dam-
aged.

Incorrectly installed or tested equipment may fail, causing
severe injury or property damage. 
Read and follow instructions in owner's manual when installing

and operating equipment. Have a trained pool professional perform all pres-
sure tests.

1. Do not connect system to a high pressure or city water system.

2. Use equipment only in a pool or spa installation.

3. Trapped air in system can cause explosion. BE SURE all air is out of system

before operating or testing equipment.

Before pressure testing, make the following safety checks:

Check all clamps, bolts, lids, and system accessories before testing.

Release all air in system before testing.

Tighten Flotec trap lids to 30 ft. lbs. (4.1 kg-cm) torque for testing.

Water pressure for test must be less than 25 PSI (172 kPa).

Water Temperature for test must be less than 100° F. (38° C).

Limit test to 24 hours. After test, visually check system to be sure it is ready
for operation. Remove trap lid and retighten hand tight only.

NOTICE: These parameters apply to Flotec equipment only. For 
non-Flotec equipment, consult manufacturer.

IMPORTANT
SAFETY 
INSTRUCTIONS

Always follow basic safety precau-
tions with this equipment, includ-
ing the following.

To reduce the risk of

injury, do not permit children to use
this product unless they are closely
supervised at all times.

This pump is  for use

with permanently installed pools and
may also be used with hot tubs and
spas if so marked. Do not use with
storable pools. A permanently
installed pool is constructed in or on
the ground or in a building such that it
cannot be readily disassembled for
storage. A storable pool is construct-
ed so that it may be readily disassem-
bled for storage and reassembled to
its original integrity.

SAVE THESE 
INSTRUCTIONS

Содержание FP6022 Series

Страница 1: ...de renseignements concernant l utilisation l installation ou l entretien Composer le 1 800 365 6832 Fran ais Pages 10 17 Instalaci n Operaci n Piezas Para mayor informaci n sobre el funcionamiento in...

Страница 2: ...ad and follow all safety instructions in this manual and on equipment Keep safety labels in good condition replace if missing or dam aged Incorrectly installed or tested equipment may fail causing sev...

Страница 3: ...n pump port If leaks occur remove pipe clean old tape rewrap with one to two additional layers of tape and remake connection NOTICE Support all piping connected with pump PIPING For pump discharge FP6...

Страница 4: ...d BONDING Fig 5 Bonding connects all metal parts around a swimming pool with a Bonding Wire to form one unit in case of short or ground there will be no electrical current flow between them Bonding is...

Страница 5: ...ess loss of consciousness or heart attack TROUBLESHOOTING GUIDE Only qualified personnel should electrically test pump motor DISCONNECT POWER TO MOTOR BEFORE WORKING ON PUMP Close suction and discharg...

Страница 6: ...53P1 C153 53P1 6 Trap Basket 1 C108 33P C108 33P C108 33P 7 Trap Cover O Ring 1 U9 229 U9 229 U9 229 8 Trap Cover 1 C3 139P1 C3 139P1 C3 139P1 9 Seal and Gasket Kit 1 FPP5006 FPP5006 FPP5006 10 Overha...

Страница 7: ...HP 3 4HP 1 Motor 60 Cycle 115V 1 A800CL A800DL 2 Seal Plate 1 C1 84P2 C1 84P2 3 Seal and Gasket Kit 1 FPP1075 FPP1075 4 Volute 1 C101 247P C101 247P 5 Overhaul Kit 1 FPP1081 FPP1082 Insert Fitting 1 U...

Страница 8: ...low General Terms and Conditions Purchaser must pay all labor and shipping charges necessary to replace prod uct covered by this warranty This warranty shall not apply to acts of God nor shall it appl...

Страница 9: ...9...

Страница 10: ...quipement Garder les tiquettes de s curit en bon tat les remplacer si elles manquent ou si elles sont endommag es Un quipement mal install ou mal contr l peut tomber en panne causer de graves blessure...

Страница 11: ...nt de refaire la connexion REMARQUE Assurer la fixation de tous les tuyaux connect s la pompe TUYAUTERIE Pour le refoulement de la pompe FP6000 utiliser un tuyau en PCV de calibre 3 81 cm 1 1 2 po ou...

Страница 12: ...joncteur de fuite la terre requis et les m thodes de contr le du disjoncteur de fuite la terre se reporter aux instructions du fabricant En cas de panne de courant voir si le disjoncteur de fuite la t...

Страница 13: ...ence ou une attaque cardiaque LOCALISATION DES PANNES Seul un personnel qualifi est autoris tester l installation lectrique du moteur de la pompe D BRANCHER L ALIMENTATION DE COURANT DU MOTEUR AVANT D...

Страница 14: ...utilis e 3 4 CV 1 CV 1 1 2 CV 1 Moteur 115 230V 1 A910DL A910EL A910FL 2 Plaque d tanch it 1 17140 0012 17140 0012 17140 0012 3 Corps du r servoir 1 C276 57P C276 57P C276 57P 4 Joint rigide 1 C20 12...

Страница 15: ...115 V 1 A800CL A800DL 2 Plaque d tanch it 1 C1 84P2 C1 84P2 3 Ensemble d tanch it 1 FPP1075 FPP1075 4 Volute 1 C101 247P C101 247P 5 Ensemble de r vision 1 FPP1081 FPP1082 Raccord ins rer 1 U78 859PA...

Страница 16: ...rais de main d uvre et d exp dition n cessaires au remplacement du produit couvert par la garantie Cette garantie ne couvrira pas les cas de force majeure et ne s appliquera pas aux produits qui du se...

Страница 17: ...17...

Страница 18: ...y en el equipo Mantenga en buen estado las etiquetas de seguri dad reemplace aquellas que falten o que est n da adas El equipo que es instalado o probado de manera incorrecta puede fallar causando les...

Страница 19: ...la cinta vieja vuelva a recubrir con una o dos capas adicionales de cinta y vuelva a hacer la conexi n AVISO Aseg rese de que todas las tuber as conectadas a la bomba tengan el soporte adecuado ENTUBA...

Страница 20: ...de conexi n a tierra del motor a la toma el ctrica de tierra EMPALME Fig 5 El empalme conecta todas las piezas met licas alrededor de una piscina con un cable de empalme para formar una unidad En caso...

Страница 21: ...ica del motor de la bomba DESCONECTE LA ENERG A EL CTRICA QUE VA AL MOTOR ANTES DE EFECTUAR TRABAJOS EN LA BOMBA Cierre las v lvulas de compuerta de succi n y descarga LA BOMBA NO SE CEBA HAY FILTRACI...

Страница 22: ...3 C20 123 C20 123 5 Cuerpo del sif n 1 C153 53P1 C153 53P1 C153 53P1 6 Filtro de cesta del sif n 1 C108 33P C108 33P C108 33P 7 Arosello de la tapa del sif n 1 U9 229 U9 229 U9 229 8 Tapa del sif n 1...

Страница 23: ...otor de 60 ciclos 115V 1 A800CL A800DL 2 Placa de sellado 1 C1 84P2 C1 84P2 3 Kit de Junta y Sello 1 FPP1075 FPP1075 4 Voluta 1 C101 247P C101 247P 5 Kit de Arreglo General 1 FPP1081 FPP1082 Ajuste de...

Страница 24: ...iciones indicadas a continuaci n T rminos y Condiciones Generales El comprador debe pagar todos los gastos de mano de obra y transporte nece sarios para reemplazar el producto cubierto por esta garant...

Отзывы: