NOTE:

These instructions are specific to ODP (Open Drip

Proof) motors.

Disassembly

1. Disconnect the pump from the power supply.
2. Drain pressure from the system by opening a faucet.
3. Drain the pump.
4. Close the isolation valves on both sides of the pump.
5. Remove the motor bolts and slide the motor / stack

assembly backwards (or lift it, if the pump is mounted
on the wall) away from the pump body flange. The
seal plate, seal plate O-Ring, seal, spacer, and pump
stack are removed together. 

6. Remove the motor end cover from the switch end of

the motor.  

Hazardous voltage. Discharge the

capacitor before proceeding.  

To discharge the capacitor, use a screwdriver with an
insulated handle. Hold the screwdriver by the handle
and move the metal part of the screwdriver to contact
both terminals of the capacitor at the same time. 

DO

NOT

touch the metal part of the screwdriver blade or

the capacitor terminals with your hand.  

7. Loosen the screw that holds the overload protector

and move it out of the way. Hold the end of the motor
shaft with a 7/16" open end wrench.

8. Use another 7/16" open end wrench on the motor

shaft. This can be accessed through the inner support
cage, or at the discharge end of the shaft. Unscrew the
stack and coupling from the motor. Remove the stack
and coupling as a unit.

Maintenance

8

For parts or assistance, call Flotec Customer Service at 

1-800-365-6832

Drain Pump 

Disconnect Power 
to Pump 

3

5

     Close Isolation
Valves to Pump

2

4

Unbolt Motor;  
Slide Motor/Stack  
Assembly Back 

     Relieve 
System Pressure

6

8

7

Remove Motor 
Canopy 

Unscrew Pump 
Shaft from Motor 
Shaft with 7/16"  
Wrench 

 

 

Hazardous  
voltage.

 

  

Discharge capacitor  
before working under 
motor canopy. 

Move Overload 

Aside and Hold Shaft  

Flats with7/16" Wrench 

Figure 7

Figure 8

Figure 9 – Capacitor location.

Capacitor 
Terminals

Protective Cover
(Pulled back to show terminals)

Figure 10 – Wrench on end shaft.

7 / 16

Disconnect from
power source.

Motor end view with
canopy removed

Overload Protector
(Moved for access)

Overload screw
(remove)

7/16" Open
End Wrench

Содержание FP5712-02

Страница 1: ...stallation Fonctionnement Pi ces Pour plus de renseignements concernant l utilisation l installation ou l entretien Composer le 1 800 365 6832 Fran ais Pages 11 19 Instalaci n Operaci n Piezas Para ma...

Страница 2: ...e may burst or pump may be damaged due to high temperatures GENERAL SAFETY To avoid risk of serious bodily injury and property damage read safety instructions carefully before installing pump Do not a...

Страница 3: ...FLOTEC have been subject to negligence abuse accident mis application tampering alteration nor due to improper installation operation maintenance or storage nor to other than normal application use or...

Страница 4: ...for suction line This pump can be disassembled for service without removing installation piping Hazardous pressure Pump body may explode if pressures exceed rated limits Maximum inlet pressure is 80 P...

Страница 5: ...ody with water NOTICE Observe the following precautions when operat ing the pump 1 Keep the motor dry Do not direct stream from pump discharge onto the motor 2 Hazardous pressure Do not run the pump w...

Страница 6: ...r lead termi nals Make sure the wires are secure 4 Attach the ground wire to the green ground screw 5 Reinstall the Motor end cover Go to Wiring Connections below ELECTRICAL Ground motor before connec...

Страница 7: ...me models are equipped with three phase motors Three phase motors require magnetic starters and can run in either direction depending on how they are connected to the power supply To Check For Proper...

Страница 8: ...7 Loosen the screw that holds the overload protector and move it out of the way Hold the end of the motor shaft with a 7 16 open end wrench 8 Use another 7 16 open end wrench on the motor shaft This...

Страница 9: ...the seal on the motor shaft Polished surfaces face each other Push the seal on evenly The seal will seat fully when the pump shaft is tightened 4 Install the spacer on the stack It fits in grooves in...

Страница 10: ..._ 3 Slinger 1 17351 0009 17351 0009 17351 0009 4 Seal Plate 1 C3 203 C3 203 C3 203 5 O Ring Seal Plate 1 U9 448 U9 448 U9 448 6 Shaft Seal 1 M13800 M13800 M13800 7 Plastic Spacer 1 P1 187P P1 187P P1...

Страница 11: ...g e suite aux temp ratures lev es CONSIGNES DE S CURIT G N RALES Pour viter tout risque de blessures corporelles graves et des dommages mat riels lire attentivement toutes les consignes de s curit ava...

Страница 12: ...modification ou d alt ration ni aux produits qui n ont pas t install s utilis s entrepos s ou entretenus correctement ni ceux qui n ont pas t utilis s ou entretenus normalement y compris mais sans s y...

Страница 13: ...on dangereuse Le corps de la pompe peut exploser si les pressions d passent les limites nominales La pression d arriv e maximale est de 551 kPa 80 lb po2 La pression de refoulement maximale est de 2 1...

Страница 14: ...ommag e suite aux temp ratures lev es qui se d velopperont 3 Ne pas utiliser un pistolet g chette standard avec cette pompe N utiliser qu un pistolet g chette dot d une caract ristique suintement auto...

Страница 15: ...ci contre LECTRICIT Mettre le moteur la terre avant de le brancher sur le courant lectrique Ne pas mettre le moteur la terre risque de causer de graves secousses lectriques ou une lectrocution mortell...

Страница 16: ...tique doit tre utilis Ces moteurs peuvent fonctionner dans un sens ou de l autre en fonction de la fa on dont ils sont branch s sur le courant d alimentation Pour v rifier le bon sens de rotation des...

Страница 17: ...tretien 17 Pour les services des pi ces ou d assistance appeler le service la client le Flotec en composant le 1 800 365 6832 Drain Pump Disconnect Power to Pump 3 1 5 Close Isolation Valves to Pump 2...

Страница 18: ...moteur Les deux surfaces polies font face l une l autre Pousser uniform ment sur le joint d tanch it Il reposera compl tement lorsque l arbre de la pompe sera serr 4 Poser la douille entretoise sur l...

Страница 19: ...2 Poign e 1 C54 21 __ __ 3 D flecteur 1 17351 0009 17351 0009 17351 0009 4 Plaque d tanch it 1 C3 203 C3 203 C3 203 5 Joint torique de la plaque d tanch it 1 U9 448 U9 448 U9 448 6 Joint d arbre 1 M1...

Страница 20: ...altas INFORMACI N GENERAL SOBRE LA SEGURIDAD Para evitar el peligro de lesiones corporales y da os materiales graves lea las instrucciones de seguridad con atenci n antes de instalar esta bomba No pe...

Страница 21: ...lusivo de FLOTEC hayan sido objeto de negligencia abuso accidente aplicaciones contraindicadas manejo indebido alteraciones ni debido a instalaci n funcionamiento mantenimiento o almacenaje incorrecto...

Страница 22: ...puede desmontarse para hacerle el mantenimiento sin sacar la tuber a de instalaci n Presi n peligrosa El cuerpo de la bomba puede explotar si las presiones sobrepasan los l mites nominales La presi n...

Страница 23: ...mba se puede estropear debido a la temperatura alta 3 No use una pistola de disparo est ndar con esta bomba Use s lo pistolas de disparo con descarga autom tica Estas se pueden adquirir como accesorio...

Страница 24: ...apa del motor Vaya a la secci n de Conexiones de Cableado a continuaci n INFORMACI N EL CTRICA Conecte el motor a tierra antes de conectarlo a la fuente de corriente el ctrica La falta de conexi n a t...

Страница 25: ...on motores trif si cos Los motores trif sicos requieren dispositivos de arranque magn ticos y pueden marchar en cualquier direcci n seg n la forma en que est n conectados a la fuente de alimentaci n V...

Страница 26: ...r Saque el conducto vertical y el empalme como una unidad ADVERTENCIA Mantenimiento 26 Para refacciones o asistencia llame a Flotec Servicios al Cliente al 1 800 365 6832 Drain Pump Disconnect Power t...

Страница 27: ...nfrentadas Oprima el sello en forma uniforme El sello quedar totalmente asentado cuando se ajuste el eje de la bomba 4 Instale el espaciador en el conducto vertical Encaja tanto en las ranuras de la p...

Страница 28: ...941ZPV 11 Cuerpo de la bomba 1 C2 90 C2 90 C2 90 12 Casco 1 P56 648SSL P56 650SSL P56 658SSL 13 Aro t rico Descarga 1 U9 430 U9 430 U9 430 14 Descarga 1 C52 8 C52 8 C52 8 15 Tornillos prisioneros 4 U...

Отзывы: