Flotec FP0S6000A Скачать руководство пользователя страница 5

4. Use only submersible power supply wires supplied by pump

manufacturer. When lowering pump into well, secure supply
wires to discharge pipe at 10 ft. (3M) intervals with Scotch #33
electrical tape. DO NOT damage pump wires.

NOTICE: 

To avoid dropping pump down well or damaging wires

or splices, 

NEVER 

allow pump wires to support weight of pump.

PUMP INSTALLATION

1. If standard air over water pressure tank is used, install two

bleeder orifices about 2 ft. (.6M) apart as shown in Fig. 12.
Orifices will automatically charge the tank with air. See Fig. 12 to
determine orifice location.

NOTICE: 

If Pre-charged tank is used, DO NOT install bleeder

orifices. If pump and pre-charged tank are replacing a standard
tank system, remove bleeder orifices before installing pump in
well.

2. To prevent losing pump down the well, connect safety rope

strong enough to support pump and drop pipe (minimum 5/16"
(

8

mm) twisted polypropylene or pronila rope) to eyelet on pump

discharge. Tie off other end of safety rope securely to well seal,
well cap or pitless adapter.

3. Discharge outlet is 1-1/4" NPT threaded. 

Use 100 PSI (6

8

9.5kPa) rated polyethylene plastic pipe for

installations up to 100' (30.5M) depth.

Use 160 PSI (1103.2 kPa) rated polyethylene plastic for installa-
tions up to 220' (67.1M) depth.

For depths beyond 220' (67.1M) use galvanized steel pipe for
the entire drop pipe.

INITIAL START-UP/NEW WELLS

NOTICE: NEVER

operate pump with discharge valve completely

closed. Pump can destroy itself if run with discharge shut off (“dead-
headed”) and warranty will be void.

NOTICE: 

To avoid sand-locking pump, follow procedure below

when starting pump for the first time. 

NEVER 

start a pump with dis-

charge completely open unless you have done this procedure first.

1. Connect a pipe elbow, a short length of pipe and a gate valve to

pump discharge at well head (see Fig. 10).

2. Mount submersible motor control (3-wire pump) or fused discon-

nect switch (2-wire pump) in a permanently weatherproof place.
Make sure that controls will not be subjected to extreme heat or
excess moisture.

3. Make sure controls are in OFF position.
4. Connect motor leads and power supply to submersible motor

control or magnetic starter (see Installation Wiring Diagrams).

DO NOT START PUMP YET.

5. Set gate valve on discharge 1/3 open; start pump (see Fig. 10).
6. Keep gate valve at this setting while water pumps out on ground.

Let run until water is clear of sand or silt. (To check solids in
water, fill a glass from pump and let solids settle out).

7. When water is completely clear at 1/3 setting, open gate valve to

approximately two-thirds open and repeat process.

8

. When water is completely clear at 2/3 setting, open gate valve

completely and run pump until water is completely clear.

9. Remove gate valve for permanent installation near tank (see

Figs. 11 and 12).

10. Install sanitary well seal or pitless adapter unit, well unit, electri-

cal conduit and surface piping. Installation must meet all code
requirements that apply.

CONNECTING TO TANK/
WATER SYSTEM

Hazardous pressure. Submersible pumps can

develop very high pressure in some situations. To prevent tank
blowup, install a pressure relief valve able to pass full pump
flow at 75 PSI (517.1 kPa) when using an air over water pres-
sure tank. Install a pressure relief valve capable of passing
entire pump flow at 100 PSI (690 kPa) when using a pre-
charged pressure tank. Install this relief valve between pump
and tank.

Pipe joint compound can cause cracking in plastics.
Use only teflon tape on joints in plastic pipe.

NOTICE: 

Allowing pump or piping system to freeze may severely dam-

age pump and will void warranty. Protect pump and entire piping system
(including pressure tank) from freezing.

PRE-CHARGED PRESSURE TANK HOOKUP

See Fig. 11 for piping connections to pre-charged pressure tank.

NOTICE: 

Check air pre-charge in tank before starting pump. Adjust

pre-charge to 2 PSI (13.

8

 kPa) below pump cut-in setting, (ie, a pre-

charge tank used with a 30-50 switch should be pre-charged with air
to 2

8

 PSI (193.1 kPa). Adjust pre-charge by adding or bleeding air

through tire valve located on top of tank. Check pre-charge annually
and adjust as needed.

STANDARD TANK HOOKUP

See Fig. 12 for piping connections to standard pressure tank and for
correct distance of bleeder orifices from pressure tank.

5

Control

center

or

electrical

disconnect

box

Temporary wiring

to control center or

electrical disconnect box

Temporary piping

Gate valve

Pump in well

Pump installation

for developing a well

689 0993

Figure 10 – Temporary Connections while cleaning well
for start-up.

Important Electrical Grounding Information

Hazardous voltage. Can shock, burn,
or kill. To reduce the risk of electrical

shock during pump operation, ground and bond the pump and
motor as follows:

A. To reduce risk of electrical shock from metal parts of the assembly

other than the pump, bond together all metal parts accessible at
the well head (including metal discharge pipe, metal well casing,
and the like). Use a metal bonding conductor at least as large as
the power cable conductors running down the well to the pump's
motor. 

B. Clamp or weld (or both if necessary) this bonding conductor to the

grounding means provided with the pump, which will be the equip-
ment-grounding terminal, the grounding conductor on the pump
housing, or an equipment-grounding lead. The equipment-ground-
ing lead, when provided, will be the conductor having green insula-
tion; it may also have one or more yellow stripes.

C. Ground the pump, motor, and any metallic conduit that carrys

power cable conductors. Ground these back to the service by con-
necting a copper conductor from the pump, motor, and conduit to
the grounding screw provided within the supply-connection box
wiring compartment. This conductor must be at least as large as
the circuit conductors supplying the pump

Save these instructions.

Содержание FP0S6000A

Страница 1: ...nance assistance Call 1 800 365 6832 English Pages 2 7 Installation Fonctionnement Pi ces Pour plus de renseignements concernant l utilisation l installation ou l entretien Composer le 1 800 365 6832...

Страница 2: ...s in well can con taminate water and cause serious mechanical damage to pump 6 Pipe joint compound can cause cracking in plastics Use only teflon tape when sealing joints in plastic pipe or connecting...

Страница 3: ...ontrol is not required See Figure 1B for correct hook up information for 230 Volt 2 Wire motors only 3 NOTE 1 Maximum wire lengths shown maintain motor voltage at 95 of service entrance voltage runnin...

Страница 4: ...to check connections E Center tubing over butt connector and apply heat evenly with torch match or lighter will not supply enough heat NOTICE Keep torch moving Too much concentrated heat may damage t...

Страница 5: ...y well seal or pitless adapter unit well unit electri cal conduit and surface piping Installation must meet all code requirements that apply CONNECTING TO TANK WATER SYSTEM Hazardous pressure Submersi...

Страница 6: ...e Union Submersible motor control 3 wire models Electrical disconnect Pressure gauge Air volume control Pressure switch To house service Gate valve Relief valve 2 ft 6m See table Figure 11 Typical Pre...

Страница 7: ...ng voltage or with those given on submersible motor control nameplate or match Use only submersible motor control designed for horsepower rating on circuit diagram inside submersible motor control cov...

Страница 8: ...plastique ou pour connecter la tuyauterie des pompes thermoplastiques PR PARATION L INSTALLATION S assurer que la pompe et le moteur n ont subi aucun dommage pendant la livraison Signaler imm diateme...

Страница 9: ...rs d alimentation en courant rouge noir et un conducteur de terre vert Commande de moteur submersible pas requise Voir la Figure 1B concernant les informations du bon branchement des moteurs de 230 vo...

Страница 10: ...s E Centrer la gaine sur le connecteur bout bout et r partir la chaleur uniform ment au moyen d un chalumeau des allumettes ou un bri quet ne fournissent pas assez de chaleur REMARQUE D placer constam...

Страница 11: ...9 D poser le robinet vanne en vue de son installation d finitive pr s du r servoir voir Fig 11 et 12 10 Monter le plombage sanitaire du puits ou l ensemble adaptateur sans cavit le puits la canalisat...

Страница 12: ...06 8 30 344 7 50 193 1 28 275 8 40 413 7 60 262 38 DISTANCE S PARANT LE CLAPET DE LA PRISE DE PURGE SUP RIEURE VOLUME DU R SERVOIR LITRES DISTANCE EN m pi gallons U S 159 42 0 6 2 310 4 82 0 9 3 454 2...

Страница 13: ...nal tique de la commande de moteur submersible submersible con ue pour tre utilis e avec la pompe l int rieur du couvercle Calibre de fil trop mince Comparer le calibre du fil avec le tableau de la pa...

Страница 14: ...a las bombas de material termopl stico PREPARATIVOS Inspeccione la bomba y el motor a su entrega para determinar la posible presencia de da os Informe de inmediato al transportista o al concesionario...

Страница 15: ...2 alambres Las bombas de 2 conductores tienen dos conductores de alimentaci n Rojo Negro y un conductor de tierra Verde No se requiere un control de motor sumergible Ver Figura 1B para la informaci n...

Страница 16: ...ez de las conexiones E Centre el tubo de pl stico sobre el conector de tope conector de cubrejunta y aplique calor en forma pareja con un soplete un f sforo o un encendedor no dan suficiente calor AVI...

Страница 17: ...v lvula de cortina para su instalaci n permanente cerca del tanque v anse las figs 11 y 12 10 Instale un sello sanitario para pozo o una unidad adaptadora la unidad del pozo los conductos para cables...

Страница 18: ...0 344 7 28 193 1 40 275 8 60 413 7 38 262 DISTANCIA DE LA V LVULA DE RETENCI N AL ORIFICIO DE PURGA SUPERIOR CAPACIDAD DEL DISTANCIA en PIES m TANQUE en GALONES l 42 159 2 0 6 82 310 4 3 0 9 120 454 2...

Страница 19: ...ontrol del motor sumergible o en el diagrama de circuito que se encuentra en el interior de la tapa del dise ado para usar con esta bomba control del motor sumergible El di metro de los conductores es...

Страница 20: ...syst me ou des produits ayant fonctionn des pressions d passant la limite maximale recommand e Les demandes de service en vertu de la pr sente garantie seront faites en retournant le produit d fectue...

Отзывы: