Page 48 of 64
versatile™ 4C Maintenance Manual—206367—Rev A
www.florencemailboxes.com
Replacement of Parcel Master Lock
versatile™ 4C mailbox suites
REQUIRED TOOLS
3/8” SOCKET WRENCH
MCGARD SCREWDRIVER (proprietary
to USPS)
ONE-WAY REMOVAL SCREWDRIVER
SLOTTED SCREWDRIVER
1 .
Open the parcel door.
• For USPS-serviced modules,
USPS personnel will be required
to perform the steps below
using a McGard Screwdriver
(see p. 6).
2 .
Remove two (2) #10-32 x 0.312” McGard
screws (
84993—USPS
) or two (2) #10-32
x 0.375” one-way SS screws (
84994—
private
) and remove the parcel-door
Arrow-Lock cover (
64216
).
3 .
Remove four (4) #10-32 SS thin hex lock
nuts with nylon (
86455
).
4 .
Remove the Arrow Lock (
USPS
) or private
lock (
206550
).
NOTE: This procedure will require opening a parcel-locker door. If the parcel
door is locked, it will need to be unlocked. For USPS-serviced modules,
the local USPS will need to be contacted to have the parcel door opened
and secured after repairs are complete.
PART #
DESCRIPTION
64042
ARROW LOCK STIFFENER PLATE (incl in K64216)
64216
PARCEL DOOR ARROW LOCK COVER (incl in K64216)
84993
#10-32 X 0.312” MCGARD SCREW
84994
#10-32 X 0.375” ONE-WAY SS SCREW (incl in K64216)
86455
#10-32 SS THIN HEX LOCK NUT W/NYLON (incl in K64216)
206550
PRIVATE LOCK
K64216
PARCEL DOOR LOCK KIT
5 .
Replace the Arrow Lock (
USPS
) or private
lock (
206550
).
6 .
Secure the lock with four (4) #10-32 SS hex
lock nuts (
86455
).
7 .
Reinstall the parcel-door Arrow-Lock cover
(
64216
) and secure with two (2) #10-32
x 0.312” McGard screws (
84993—USPS
)
or two (2) #10-32 x 0.375” one-way SS
screws (
84994—private
).
8 .
Close the parcel door.
Confidential & Proprietary for Florence and Clients Only -- Do Not Distribute