September 6, 2017
84
Configuration and Operation
CM-6212 H1-I User and Installation Guide
To set a schedule
1.
Select
By schedule
. The message “Please Select” is displayed.
2.
Click
Please select
. A drop-down menu opens.
3.
From the drop-down menu, select a schedule from 1 to 10. The selected schedules are displayed
in a horizontal field above the drop-down menu.
4.
Click
SAVE
.
To configure motion detection settings
1.
Sampling pixel interval
[
1-10]
– Select a number from 1-10. The default value is 1. If the value is set
as 3, within the detection region, the system will take one sampling pixel for every 3 pixels by
each row and each column (see the figure below).
Pixel Interval Illustration
2.
Detection level
[
1-100]
– Select a number from 1-100. The default level is 40. This sets detection
level for each sampling pixel; the smaller the value, the more sensitive it is.
3.
Sensitivity level [1-100]
– Select a number from 1-100. The default level is 60, which means if 40%
or more sampling pixels are detected differently, the system will detect motion. The bigger the
value, the more sensitive it is and more colored segments will be displayed in the Motion Indication
Bar.
4.
Time interval (sec) [0-7200]
– Select a number from 0-7200 (seconds). The default interval is 10.
The value is the interval between each detected motion.
Set Triggered Actions
The Administrator can specify alarm actions to be taken when motion is detected. See the
details. The options are listed as follows:
·
Enable alarm output
– Check this box and select the predefined type of alarm output
(low
or
high
)
to enable alarm relay when tampering is detected.
·
Record video clip
– Select this box to store the motion detection alarm recording in a microSDXC
card or on the NAS when tampering is detected.
·
Send alarm message by FTP
– Select whether to send an alarm message by FTP when motion is
detected.
·
Upload image by FTP
– Select this box in order to upload an image to a designated FTP site when
motion is detected according to various parameters.
·
Send HTTP notification
– Check this box to send a notification by HTTP.
·
Send alarm message by E-Mail
– Select whether to send an alarm message by e-mail when
motion is detected.
Содержание Quasar Gen II Series CM-6212 H1-I
Страница 1: ...Quasar Gen II User and Installation Guide CM 6212 H1 I Ver 1 September 6 2017 i...
Страница 4: ...September 6 2017 CM 6212 H1 I User and Installation Guide iv...
Страница 12: ...September 6 2017 CM 6212 H1 I User and Installation Guide 6...
Страница 16: ...September 6 2017 CM 6212 H1 I User and Installation Guide 10...
Страница 22: ...September 6 2017 CM 6212 H1 I User and Installation Guide 16...
Страница 24: ...September 6 2017 CM 6212 H1 I User and Installation Guide 18...
Страница 32: ...September 6 2017 CM 6212 H1 I User and Installation Guide 26...
Страница 42: ...September 6 2017 CM 6212 H1 I User and Installation Guide 36...
Страница 126: ...September 6 2017 CM 6212 H1 I User and Installation Guide 120...