September 6, 2017
14
Hardware Description
CM-6212 H1-I User and Installation Guide
3.3.1
Waterproofing the Cable Connectors
Follow the instructions below to waterproof the connectors for the different types of cables included in the
system cable. The cables are shown below.
System Cable
Standard RJ45 Cable
Optional IP66 RJ45 Cable
Camera Cables
To waterproof the system cable
1.
Connect all the required devices to the system cable. See figure above.
2.
Coat the joints with silicone gel. There should be no gap between the connectors and the cables.
For alarm I/O connector and power connector, make sure the side with wires attached is also
sealed with silicone gel.
3.
Seal the end of the rubber coating of the system cable as indicated in the figure below. Use
enough silicone gel to fill in the hose and wrap around each wire in order to properly waterproof the
cable.
System Cable Hose and Wiring
To waterproof the RJ45 cable
1.
Plug the Ethernet cable to the connector of the RJ45 cable.
RJ45 Connector and Plug
2.
Coat the joint with silicone gel. Make sure there is no gap between the Ethernet cable and the
connector in order to properly waterproof the cable.
Содержание Quasar Gen II Series CM-6212 H1-I
Страница 1: ...Quasar Gen II User and Installation Guide CM 6212 H1 I Ver 1 September 6 2017 i...
Страница 4: ...September 6 2017 CM 6212 H1 I User and Installation Guide iv...
Страница 12: ...September 6 2017 CM 6212 H1 I User and Installation Guide 6...
Страница 16: ...September 6 2017 CM 6212 H1 I User and Installation Guide 10...
Страница 22: ...September 6 2017 CM 6212 H1 I User and Installation Guide 16...
Страница 24: ...September 6 2017 CM 6212 H1 I User and Installation Guide 18...
Страница 32: ...September 6 2017 CM 6212 H1 I User and Installation Guide 26...
Страница 42: ...September 6 2017 CM 6212 H1 I User and Installation Guide 36...
Страница 126: ...September 6 2017 CM 6212 H1 I User and Installation Guide 120...