20
Onboard Weighing |
FT-30M
| www.flintec.com
Calibration - Dual Channel
Calibration
Dual mode allows two input channels to be calibrated separately and independently. The displayed weight is the summed total of
Channel 1 and Channel 2 (Ch1+Ch2). Dual allows load cell and sensor types with different outputs to be installed to the same vehicle.
On flat and level ground weigh and enter Tare (unladen) weights for channel 1 & 2. Load the vehicle to its legal maximum. Weigh and
enter the vehicle Net Payload for channel 1 & 2. Example shown is an articulated truck with 5th wheel load cells fitted to the tractor
unit & wired to channel 1 (Ch1). Air pressure sensors are fitted to the trailer & wired to channel 2 (Ch2).
1� Home
Navigate to the menu.
Press :
2� Menu
Navigate through the User Functions.
Press :
3� Settings
Enter the Settings menu. (Pin code protected)
Press :
4� Pin code
Swipe up or down to enter pin code.
Press :
5� Set Up Menu
Enter the Weight Settings menu.
Press :
6� Weight Settings
Enter the Truck Modes menu.
Press :
7� Modes
Select Dual Channel mode.
Press
8� Set Up Menu
Enter the Calibration Menu.
Press
v1_000022_FT-30M 21/06/2016