23
Onboard Weighing |
FT-30M
| www.flintec.com
29� Calibration Complete
Dual channel calibration is complete.
Press :
30� Home Screen
Home screen displays the Gross weight by default.
Press :
to toggle the Net weight to be displayed.
31� Home Screen- Net
Home displaying Net.
Press :
to toggle back to Gross weight.
28� Channel 2 - Trailer Net Calibration Done
The green tick confirms calibration for Channel 2 is complete.
Press :
Calibration - Dual Channel
27� Trailer Net mV/V
Confirm the trailer Net mV/V.
Press :
*mV/V is the signal level from the load cells and must be stable.
Flickering indicates a problem with a load cell, connection or the load is
moving. Values are different from the Tare mV/V.
*Tare + Net = Gross. (5,840 + 27,840kg = 33,680kg).
*Ch1 + Ch2 Gross = 26,740 + 33,680kg = 60,420kg.
v1_000025_FT-30M 21/06/2016