2. Operation (Restoration & Discharge)
PROGRAM MODE – PULSE SCENARIOS
Restoration(regeneration charge) Method – Pulse Scenarios (Patterns)
( V = Voltage, A = Ampere, T = Time )
Pulse 1
Restoration Pulse1 Scenario :
①
Start Charging with Set A.
②
When Actual Voltage reaches Set V, it will
finish the Mode regardless of Set T.
②
When it reaches Set T, it will also finish the Mode
even though Actual V has not yet reached Set V.
“Constant Current” Charging will be applied
Pulse 2
Restoration Pulse2 Scenario :
①
Start Charging with Set A until Actual Voltage
reaches Set Voltage. (Constant current)
②
When Actual V reaches Set V, maintain Set V until
Set Time by controlling Actual Ampere.
(Constant Voltage).
③
When it reaches Set time, it will finish the Mode.
You should check specification & conditions of used batteries before you input Set V, Set A
and Set Time for regeneration of batteries. Wrong set values will cause damages to batteries
due to over charge or other reasons.
42