UMPIOXR400V2-7-1EN, 2012-07-01
19
6 Installation of PIOX R400, R400B, R400C, R400A2
•
Push the sensor cable through the cap nut and the compression part.
•
Prepare the sensor cable with the cable gland (see Fig. 6.9).
•
Cut the outer shield and brush it back over the compression part.
•
Screw the gasket ring side of the basic part in the housing.
•
Insert the sensor cable in the housing.
•
Fix the cable gland by screwing the cap nut on the basic part.
•
Connect the leads to the terminals of the transmitter (see Fig. 6.9).
Fig. 6.9: Direct connection of sensor PIOX R400 with transmitter PIOX TR374
terminal
sensor cable
1
measu
ring
ch
ann
el A
V+
yellow
V-
green
A+
brown
B-
white
3a
gray
5a
pink
measu
ring
ch
ann
el B
2V+
yellow
2V-
green
2A+
brown
2B-
white
6b
gray
9b
pink
70 mm
10
mm
outer
shield
terminal strip KL1
terminal strip KL1:
sensor
cable
Preparation
of extension cable and
sensor cable:
transmitter
1
No terminals are provided for
connecting the red and blue cables.
Important!
To ensure good high frequency shielding, it is important
to provide good electrical contact between the outer
shield and the cable gland and hence to the housing of
the transmitter. Cut the outer shield and brush it back as
shown in the figure.
Attention!
To connect the sensor cable to the
transmitter, use only metallic cable glands.
outer
shield