20
UMPIOXR400V2-7-1EN, 2012-07-01
6 Installation of PIOX R400, R400B, R400C, R400A2
6.3.2 Connection via Junction Box
Connection of the Extension Cable with the Transmitter
•
Remove the blind plug for the connection of the sensor (see Fig. 6.10).
•
Open the cable gland of the extension cable. The compression part remains in the cap nut (see Fig. 6.8).
•
Push the extension cable through the cap nut and the compression part.
•
Prepare the extension cable with the cable gland (see Fig. 6.10).
•
Cut the outer shield and brush it back over the compression part.
•
Screw the gasket ring side of the basic part in the housing.
•
Insert the extension cable in the housing.
•
Fix the cable gland by screwing the cap nut on the basic part.
•
Connect the leads to the terminals of the transmitter (see Fig. 6.10).
Connection of the Extension Cable with the Junction Box
•
Remove the blind plug from the junction box (see Fig. 6.10).
•
Open the cable gland of the extension cable. The compression part remains in the cap nut (see Fig. 6.8).
•
Push the extension cable through the cap nut, the compression part and the basic part.
•
Insert the extension cable in the junction box.
•
Prepare the extension cable with the cable gland.
•
Cut the outer shield and brush it back.
•
Pull the extension cable back until the brushed back outer shield is below the shield terminal of the junction box
(see Fig. 6.10).
•
Screw the gasket ring side of the basic part in the junction box.
•
Fix the cable gland by screwing the cap nut on the basic part.
•
Fix the extension cable and the outer shield to the shield terminal of the junction box (see Fig. 6.10).
•
Connect the leads to the terminals of the junction box (see Fig. 6.10).
Connection of the Sensor Cable with the Junction Box
•
Remove the blind plug from the junction box (see Fig. 6.10).
•
Open the cable gland of the sensor cable (see Fig. 6.8). The compression part remains in the cap nut.
•
Push the sensor cable through the cap nut, the compression part and the basic part.
•
Prepare the sensor cable with the cable gland.
•
Insert the sensor cable in the junction box.
•
Screw the gasket ring side of the basic part in the junction box.
•
Fix the cable gland by screwing the cap nut on the basic part.
•
Connect the leads to the terminals of the junction box (see Fig. 6.10).
Attention!
The outer shield of the extension cable must not have electrical contact to the junction box.
The extension cable has to remain insulated completely up to the shield terminal.
Attention!
The outer shield of the sensor cable must not have electrical contact to the junction box.