manual – force
IQ
5
www.flexiforce.com
5
2.
Force70XQ/100XQ/100XC/140XQ operator
2.1.
Safety instructions
•
Follow all instructions since incorrect installation can lead to severe injury.
•
Check that the temperature range marked on the operator is suitable for the location.
•
Check that the door is moving smooth and correct before assembling the operator.
•
Check that the door is in good mechanical condition and is correctly balanced.
•
After installation, ensure that the mechanism is properly adjusted and that the protection system
and any manual release function correctly.
•
Ensure that entrapment between the driven part and the surrounding fixed parts due to the
opening movement of the driven part is avoided.
•
External push button units are to be located within direct sight of the door but away from
moving parts. Unless it is key operated, it is to be installed at a minimum height of 1,5 m and not
accessible to the public.
2.2.
Preparation
Before you start make sure that the following preparations are done:
•
Approval/communication with customer completed.
•
Materials on site are complete.
•
All measurements are correct.
2.3.
Electrical preparations
The manually operated door needs no electrical supply. For an electrically operated door, the following
environment criteria and electrical supplies are required for the operator to function properly:
force100XQ/XC
force140XQ
force70XQ
Voltage supply: +/‐ 10%
400V AC 3‐phase 50Hz, 10A 400V AC 3‐phase 50Hz, 10A 230V AC 1‐phase 50Hz, 10A
Power:
0,37 kW
0,55 kW
0,50 kW
Degree of protection:
IP54
IP54
IP54
Weight:
13 kg
13 kg
11,5 kg
Allowed door weight, max.:
400 kg
650 kg
350 kg
Temperature working range:
‐15 °C to +50 °C
‐15 °C to +50 °C
‐10 °C to +40 °C
Operating factor, Duty cycle:
40% S3 10 min. Intermittent 40% S3 10 min. intermittent 25% S3 10 min. intermittent
Dimensions force..XQ (hxwxd):
375 x 260 x 110 mm
375 x 260 x 110 mm
380 x 110 x 250
mm
Dimensions force..XC (hxwxd):
425 x 110 x 260
mm
Содержание ForceIQ Force100XC
Страница 1: ...forceIQ manual manual version 3 0 software version 1 147 c 1 DEF5000 EN ...
Страница 34: ......
Страница 35: ...manual forceIQ 35 www flexiforce com 34 Appendix 6 1 Additional function terminals ...
Страница 36: ...manual forceIQ 36 www flexiforce com 35 Terminal group A Terminal group B ...
Страница 37: ...manual forceIQ 37 www flexiforce com Terminal group C Terminal group D ...