4.2. forceLD: loop detector
This is a double detector to connect 2 loops. The connection is at terminal KL23 in the ForceIQ.
The detailed adjustments are described in the supplied manual and the wiring is shown in the electrical drawing.
No need to adjust settings in the menu of the ForceIQ.
Terminal
Function
1 / 2
Loop 1
3 / 4
Loop 2
Terminal
Function
1 / 2
Switching output 1
3 / 4
Switching output 2
5
+ 24V DC
6
GND
Setting DIP‐switches:
DIP=switch
Function
1
Frequency adjustment
2
Frequency adjustment
3
Sensitivity loop 1
4
Sensitivity loop 1
5
Sensitivity loop 2
6
Sensitivity loop 2
7
Direction detection
8
Frequency boost (truck with buildup)