49
ARPEX 8706 en
Operating instructions 10/2017
Remove the intermediate unit (see figs. 6 to 16).
WARNING
Serious injury
Risk of serious injury through falling coupling parts and/or flying fragments and/or risk of damage to the
coupling.
Secure all coupling parts against falling before undoing the screw connection.
After demounting the cheesehead bolts of the fastening (see figure 47) must imperatively be undone
again, so that the plate pack is detensioned and the cheesehead bolts remain only loosely screwed in.
Remove the cheesehead bolts (see figure 47) for transport purposes, so that the distance bushes
(see figure 47) can be inserted again. After this, insert the cheesehead bolts again and tighten them
handtight.
Fig. 47:
Inserting the fastening
WARNING
Serious injury
Risk of serious injury through flying fragments and/or risk of damage to the coupling.
Fit the transport lock of the plate pack before transport.