23
ARPEX 8706 en
Operating instructions 10/2017
5.5.2
Type
XVX
1
3
2
1
4
5
2
*)
"Y"
"Y"
Detail "Y"
X
V
X
Fig. 14:
Type
XVX
1
"
X
" module
2
Screw connection of flange
3
"
V
"-spacer (intermediate unit)
4
Collar bolt
5
Threaded bush
"Y"
Fastening
*
)
The plate packs must not be demounted or retightened!
The plate packs have been secured for the transport with special fastenings (collar bolts and threaded
bushes; see detail
"Y"
in figure 14).
The screw connections of the flanges (see figure 14) are delivered in separate packing units for each
coupling. The packing unit may contain additional spare screw connections.
Depending on the coupling version, shims may be delivered, which are used for compensating the shaft
distance
"DBSE"
. The procedure is described in item 6.6.