45
ARPEX 8706 en
Operating instructions 10/2017
xy
AAA
AAA
AAA
AAA
1
3
4
4
3
2
Fig. 41:
Fitting the dummy flange
(basic drawing
BVB
and
MHM, XVX
identical to
BVB
)
1
"
B
" module
2
"
M
" hub
3
Dummy flange
4
Screw connection of flange
xy
legible from one direction
The screw connections of the flanges (see figure 41) are delivered in separate packing units for each
dummy flange.
NOTICE
Damage to coupling, disruptions
Damage to the coupling and/or disruptions through the incorrect use of screw connections of the flanges.
The screw connections of the flanges have been checked by weight and must always be used or
replaced in sets.
WARNING
Risk of serious injury through flying fragments
Risk of serious injury through flying fragments and/or risk of damage to the coupling.
While running a test of a module with plate pack the plate packs must be fastened as described in item
6.10.2.