If necessary, move axially the shaft ends of the machines to be joined together and after fitting the
intermediate unit set exactly to the dimension
"DBSE"
(see
orderspecific drawing of the coupling
).
6.8.2
Procedure applying to modules with threaded bush
Observe the safety instructions in section 6.1, "General information on fitting"!
The design of the fastening is shown on the orderspecific drawing of the coupling.
Unscrew the collar bolt from the fastening and remove the threaded bushes (see figure 27).
1
2
1
Fig. 27:
Unscrewed threaded bush of the fastening
1
Collar bolt
2
Threaded bush
Screw in the collar bolts of the fastening again. The plate packs of the fitted
"X"
modules are clinched
axially by tightening the bolts. Tighten the bolts of the coupling flanges as fas as they will go (figure 27).
The intermediate unit
"V"
spacer (see figures 7 and 14) must fit between the fitted coupling parts.
If necessary, additionally move axially the shaft ends of the machines to be joined together and after fitting
the intermediate unit set exactly to the dimension
"DBSE"
(see
orderspecific drawing of the coupling
)