background image

FTS 350i-2 USER MANUAL 

Flash Technology, LLC 

Revision A – 4/21/2022 

15 

Table 4-2 – Troubleshooting - Beacon Does Not Flash at Night 

Step  Check/Test/Action 

 

Action 

2a 

Is AC power applied? 

Yes 
No 

Go to Step 2b. 
Correct problem. 

2b 

Does beacon flash after being covered for 1 
minute? 

Yes 
No 

Go to Step 2c. 
Replace unit. 

2c 

Is there continuity between the RED and 
ORANGE conductors?  
--OR

— 

Does the beacon respond with a single quick blink 
to a button press of 1 on the remote control? 

Yes 
No 

Beacon is operational. 
Replace the unit. 

 

Table 4-3 – Troubleshooting – Beacon Flashes, But Not in Sync 

Step  Check/Test/Action 

 

Action 

3a 

Does GPS antenna (located in top of beacon) 
have an unobstructed view of the sky? See 
Section 2.1 

Yes 
No 

Go to Step 3b. 
Correct problem. 

3b 

After 10 minutes of power on, is there continuity 
between the RED and ORANGE conductors? 
--OR

— 

Does the beacon respond with a single quick blink 
to a button press of 1 on the remote control? 

Yes 
No 

Beacon is operational. 
Replace the unit 

 

Table 4-4 – Troubleshooting - Beacon Flashes in Daytime 

4.3 BEACON REPAIR PROCEDURES 

Warning: Read th

Personnel Hazard Warning

 (page 3) now. Remove power from all wiring and circuitry before 

installing or performing work on the beacon. It is the responsibility of the installer to comply with all applicable 
electrical codes.  

Note: While performing the following steps, check for any loose connections and other damaged components. 

4.3.1 REPLACE THE BEACON 

FTS 350i-2 Part Number: F1350200 

BEACON REMOVAL 

Disconnect the beacon’s cable pigtail from the power source and any monitoring equipment. Unfasten the 
hardware that holds the 350i unit to the structure or mounting bracket. Remove the beacon.  

BEACON REPLACEMENT 

Refer to 

Section 2

 (page 8). 

Step  Check/Test/Action 

 

Action 

Is the light collector (located near marked corner 
of beacon) obstructed? Check for any foreign 
matter on top of beacon.  

Yes 
No 

Correct problem  
Replace unit 

Содержание FTS 350i-2

Страница 1: ...FTS 350i 2 USER MANUAL Flash Technology LLC Revision A 4 21 2022 1 FTS 350i 2 LED Integrated Beacon Red LED Obstruction Lighting System Reference Manual Part Number F7913502...

Страница 2: ...e every effort has been made to ensure that the information in this manual is complete accurate and up to date Flash Technology assumes no liability for damages resulting from any errors or omissions...

Страница 3: ...l times when you expose circuits and components and when you operate maintain or service this equipment AVOID TOUCHING LIVE CIRCUITS Avoid touching any component or any part of the circuitry while the...

Страница 4: ...tifications 6 1 2 Beacon Component Identification 7 Section 2 Installation Unpacking Mounting Wiring and Checkout 8 Warning 8 Installation Procedures 8 2 1 Unpack the FTS 350i 2 8 2 2 Mount the Beacon...

Страница 5: ...2 1 Beacon flashhead Dimensions and Mounting Outline 9 Figure 2 2 Mounting Outline with Adapter Bracket 10 LIST OF TABLES Table 2 1 Standard Power Alarm Connections 10 Table 2 2 Power Alarm and Radar...

Страница 6: ...sures maximum visibility to pilots in all circumstances while providing significant electrical power savings over incandescent fixtures The lighting system is equipped with an alarm contact to monitor...

Страница 7: ...N COMPONENT IDENTIFICATION Figure 1 1 Beacon External View Figure 1 2 Beacon Base Assembly Fresnel Lens and LED Engine Assembly GPS Antenna Light Collector Photodiode Cable Pigtail Base Assembly Surge...

Страница 8: ...ght that interferes with mode change operation The GPS antenna located on top of the beacon must have an unobstructed view of the sky for proper reception and synchronization The beacon is equipped wi...

Страница 9: ...FTS 350i 2 USER MANUAL Flash Technology LLC Revision A 4 21 2022 9 Note All dimensions are in inches millimeters in brackets Figure 2 1 Beacon flashhead Dimensions and Mounting Outline...

Страница 10: ...per operation and protection of the beacon Optional 75 foot 100 foot and custom cables lengths are available Optional dry contact monitoring connections permit monitoring of lighting system operation...

Страница 11: ...ire back do not use Bare Drain Cut wire back do not use 2 4 VERIFYING OPERATION Apply power to the beacon and verify operation 2 4 1 POWER UP When powered up the beacon will begin flashing after sever...

Страница 12: ...ptional 10 conductor cable provides the same connections and adds connections for the auxiliary control input 2 wires The AC input power requirement is 100 240 VAC 50 60Hz The dry contact alarm connec...

Страница 13: ...ctive after 19 hours without a mode change Disabled PD alarm functions are turned OFF for areas that experience extended day nighttime conditions Pressing button 3 will show the current PD Alarm setti...

Страница 14: ...n and the Induced LI flash alarms from button 8 Also cancels the 15 min forced red mode on power up SECTION 4 MAINTENANCE AND TROUBLESHOOTING 4 1 MAINTENANCE No regularly scheduled maintenance is requ...

Страница 15: ...respond with a single quick blink to a button press of 1 on the remote control Yes No Beacon is operational Replace the unit Table 4 4 Troubleshooting Beacon Flashes in Daytime 4 3 BEACON REPAIR PROC...

Страница 16: ...TEGRATED LED BEACON 1350200 5 3 RMA POLICY If any system or part s purchased from Flash Technology needs to be returned for any reason subject to the warranty policy please see the current RMA policy...