Remote Button 

Action 

Description / Notes 

PWR 

Toggle between Red Night (Flashing 
ON) and Day (Flashing OFF) 

30 min overrides 

On a unit powering up, the 1st button press triggers 
red night override. 

Verify alarm state  
 1 blink = status ok 
 2 blinks = flash alarm (red or IR) 
 3 blinks = GPS sync alarm 
 4 blinks = PD alarm 

If more than 1 alarm is active, then the alarm highest 
in that hierarchy will show.  

Ex: Red flash alarm + PD alarm will cause 2 blinks. 

Toggle flash rate 

 

FPM = Flashes per minute 

30 FPM = Current FAA standard 
20 FPM = Sync with existing 
installations and/or previous FAA 
standard 

Pressing button 2 will show the current flash rate: 

 

1 blink for 20 fpm 

 

2 blinks for 30 fpm 

Pressing 2 again within 15 seconds will toggle the 
setting.  

Ex: If it was set to 20 fpm, then the fpm will now be 
set to 30 and the beacon will provide 2 blinks to 
indicate the new setting. 

Toggle PD alarm disable 

PD = Photodiode 

Enabled = Alarm will active after 
19 hours without a mode change 
Disabled = PD alarm functions are 
turned OFF (for areas that 
experience extended 
day/nighttime conditions) 

Pressing button 3 will show the current PD Alarm 
setting:  

 

1 blink for PD Alarm Enabled 

 

2 blinks for Disabled 

Pressing 3 again within 15 seconds will toggle the 
setting.  

Ex: If it was set to PD Alarm Enabled, then the PD 
Alarm will become Disabled and the beacon will 
provide 2 blinks to indicate the new setting. 

Toggle PD disable (24hr red mode) 

PD = Photodiode 
Enabled = Auto ON and OFF (based 
on FAA regulations for light levels) 
Disabled = 24 Hour ON red flashing 

Pressing button 4 will show the current PD Defeat 
setting:  

 

1 blink for PD Defeated 

 

2 blinks for PD Engaged 

Pressing 4 again within 15 seconds will toggle the 
setting.  

Ex: If it was set to PD Defeated, then the PD will 
become engaged and the beacon will provide 2 blinks 
to indicate the new setting. 

Toggle GPS sync alarm disable 

GPS = Global positioning system 
Enabled = Alarm will activate if 
unable to find enough satellites 
Disabled = GPS alarm functions are 
turned OFF 

Pressing button 5 will show the current GPS Alarm 
setting:  

 

1 blink for GPS Alarm Enabled 

 

2 blinks for Disabled 

Содержание FTS 350i-2

Страница 1: ...FTS 350i 2 USER MANUAL Flash Technology LLC Revision A 4 21 2022 1 FTS 350i 2 LED Integrated Beacon Red LED Obstruction Lighting System Reference Manual Part Number F7913502...

Страница 2: ...e every effort has been made to ensure that the information in this manual is complete accurate and up to date Flash Technology assumes no liability for damages resulting from any errors or omissions...

Страница 3: ...l times when you expose circuits and components and when you operate maintain or service this equipment AVOID TOUCHING LIVE CIRCUITS Avoid touching any component or any part of the circuitry while the...

Страница 4: ...tifications 6 1 2 Beacon Component Identification 7 Section 2 Installation Unpacking Mounting Wiring and Checkout 8 Warning 8 Installation Procedures 8 2 1 Unpack the FTS 350i 2 8 2 2 Mount the Beacon...

Страница 5: ...2 1 Beacon flashhead Dimensions and Mounting Outline 9 Figure 2 2 Mounting Outline with Adapter Bracket 10 LIST OF TABLES Table 2 1 Standard Power Alarm Connections 10 Table 2 2 Power Alarm and Radar...

Страница 6: ...sures maximum visibility to pilots in all circumstances while providing significant electrical power savings over incandescent fixtures The lighting system is equipped with an alarm contact to monitor...

Страница 7: ...N COMPONENT IDENTIFICATION Figure 1 1 Beacon External View Figure 1 2 Beacon Base Assembly Fresnel Lens and LED Engine Assembly GPS Antenna Light Collector Photodiode Cable Pigtail Base Assembly Surge...

Страница 8: ...ght that interferes with mode change operation The GPS antenna located on top of the beacon must have an unobstructed view of the sky for proper reception and synchronization The beacon is equipped wi...

Страница 9: ...FTS 350i 2 USER MANUAL Flash Technology LLC Revision A 4 21 2022 9 Note All dimensions are in inches millimeters in brackets Figure 2 1 Beacon flashhead Dimensions and Mounting Outline...

Страница 10: ...per operation and protection of the beacon Optional 75 foot 100 foot and custom cables lengths are available Optional dry contact monitoring connections permit monitoring of lighting system operation...

Страница 11: ...ire back do not use Bare Drain Cut wire back do not use 2 4 VERIFYING OPERATION Apply power to the beacon and verify operation 2 4 1 POWER UP When powered up the beacon will begin flashing after sever...

Страница 12: ...ptional 10 conductor cable provides the same connections and adds connections for the auxiliary control input 2 wires The AC input power requirement is 100 240 VAC 50 60Hz The dry contact alarm connec...

Страница 13: ...ctive after 19 hours without a mode change Disabled PD alarm functions are turned OFF for areas that experience extended day nighttime conditions Pressing button 3 will show the current PD Alarm setti...

Страница 14: ...n and the Induced LI flash alarms from button 8 Also cancels the 15 min forced red mode on power up SECTION 4 MAINTENANCE AND TROUBLESHOOTING 4 1 MAINTENANCE No regularly scheduled maintenance is requ...

Страница 15: ...respond with a single quick blink to a button press of 1 on the remote control Yes No Beacon is operational Replace the unit Table 4 4 Troubleshooting Beacon Flashes in Daytime 4 3 BEACON REPAIR PROC...

Страница 16: ...TEGRATED LED BEACON 1350200 5 3 RMA POLICY If any system or part s purchased from Flash Technology needs to be returned for any reason subject to the warranty policy please see the current RMA policy...

Отзывы: