background image

FTS 350i-2 USER MANUAL 

Flash Technology, LLC 

Revision A – 4/21/2022 

SECTION 1 – OVERVIEW 

Flash Technology’s FTS 350i-2 is a LED-based, FAA L-864 flashing red beacon. Prewired with power and alarm 
cables and equipped with an integrated controller, the unit is ready for operation on connection with a customer 
supplied AC line. The FTS 350i-2 is also available with an optional ADLS compatible radar interface. 

The beacon is designed for the safety lighting of wind turbines, towers, flare stacks, chimneys, offshore oil 
platforms, petrochemical facilities and other obstructions to aerial navigation, as specified by the FAA, FCC, ICAO 
and Transport Canada. It has been certified to be in compliance with the requirements of each of these 
organizations. 

Shown in 

Figure 1-1

 (page 6), the FTS 350i-2 (hereafter referred to as the beacon) operates from a 100-240 VAC 

50/60 Hz AC line. The integrated controller flashes the beacon at night and synchronizes with other Flash 
Technology beacons via its incorporated GPS receiver/antenna.  

28 high performance red LEDs provide the FAA required visible light output. Seven infrared (IR) LEDs ensure 
visibility of the obstruction light to pilots flying with night vision aids (NVG/NVIS). The combination of red (620nm) 
LEDs and IR (850nm) LEDs ensures maximum visibility to pilots in all circumstances while providing significant 
electrical power savings over incandescent fixtures. 

The lighting system is equipped with an alarm contact to monitor its operation. Beacon operation, GPS sync and 
mode change function is monitored with alarms generated for any failure.  

This manual provides guidance and recommendations for the installation, inspection and testing of the beacon 
assembly. Please read this document in its entirety before installing the beacon. 

1.1 SPECIFICATIONS 

 

Type 

FTS 350i-2: FAA L-864 Red Obstruction Light 

Flash Rate* 

20/30 flashes per minute (FPM) 

Intensity 

2,000 ± 25% ECD 

AC Voltage  

100-240V AC 50/60 Hz 

Power Consumption 

Flash rate (200ms flash duration) 
20 fpm 

30 fpm 

Standby 

6 Watts 

9 Watts 

0.5 Watts 

Peak VA 

100 (during flash) 

Operating Temperature 

-40°F to +131°F (-40°C to +55°C) 

Height / Width  

4.40” x 9.43” (112mm x 240mm) 

Bolt Hold Down  

7.88” (200mm) 
13.25” (337 mm) (With Adaptor Bracket) 

Weight** 

2.9 lb. (1.3 kg); With 50ft of 5 conductor cable: 3.7 lb. (1.7 kg) 
2.9 lb. (1.3 kg); With 50ft of 10 conductor cable: 6.5 lb. (3 kg) 

* Current FAA regulations require a flash rate of 30 FPM. 

1.1.1 REGULATORY COMPLIANCE AND CERTIFICATIONS  

• 

Compliant to Federal Aviation Administration (FAA): AC 150/5345-43J 

• 

Compliant to Canadian Aviation Regulations (CAR): Standard 621 

• 

Compliant to International Civil Aviation Organization (ICAO): Aerodromes, Annex 14, Volume 1, Eighth 
Edition, dated July 2018 (Medium Intensity, Type B Obstacle Light – Red) 

Содержание FTS 350i-2

Страница 1: ...FTS 350i 2 USER MANUAL Flash Technology LLC Revision A 4 21 2022 1 FTS 350i 2 LED Integrated Beacon Red LED Obstruction Lighting System Reference Manual Part Number F7913502...

Страница 2: ...e every effort has been made to ensure that the information in this manual is complete accurate and up to date Flash Technology assumes no liability for damages resulting from any errors or omissions...

Страница 3: ...l times when you expose circuits and components and when you operate maintain or service this equipment AVOID TOUCHING LIVE CIRCUITS Avoid touching any component or any part of the circuitry while the...

Страница 4: ...tifications 6 1 2 Beacon Component Identification 7 Section 2 Installation Unpacking Mounting Wiring and Checkout 8 Warning 8 Installation Procedures 8 2 1 Unpack the FTS 350i 2 8 2 2 Mount the Beacon...

Страница 5: ...2 1 Beacon flashhead Dimensions and Mounting Outline 9 Figure 2 2 Mounting Outline with Adapter Bracket 10 LIST OF TABLES Table 2 1 Standard Power Alarm Connections 10 Table 2 2 Power Alarm and Radar...

Страница 6: ...sures maximum visibility to pilots in all circumstances while providing significant electrical power savings over incandescent fixtures The lighting system is equipped with an alarm contact to monitor...

Страница 7: ...N COMPONENT IDENTIFICATION Figure 1 1 Beacon External View Figure 1 2 Beacon Base Assembly Fresnel Lens and LED Engine Assembly GPS Antenna Light Collector Photodiode Cable Pigtail Base Assembly Surge...

Страница 8: ...ght that interferes with mode change operation The GPS antenna located on top of the beacon must have an unobstructed view of the sky for proper reception and synchronization The beacon is equipped wi...

Страница 9: ...FTS 350i 2 USER MANUAL Flash Technology LLC Revision A 4 21 2022 9 Note All dimensions are in inches millimeters in brackets Figure 2 1 Beacon flashhead Dimensions and Mounting Outline...

Страница 10: ...per operation and protection of the beacon Optional 75 foot 100 foot and custom cables lengths are available Optional dry contact monitoring connections permit monitoring of lighting system operation...

Страница 11: ...ire back do not use Bare Drain Cut wire back do not use 2 4 VERIFYING OPERATION Apply power to the beacon and verify operation 2 4 1 POWER UP When powered up the beacon will begin flashing after sever...

Страница 12: ...ptional 10 conductor cable provides the same connections and adds connections for the auxiliary control input 2 wires The AC input power requirement is 100 240 VAC 50 60Hz The dry contact alarm connec...

Страница 13: ...ctive after 19 hours without a mode change Disabled PD alarm functions are turned OFF for areas that experience extended day nighttime conditions Pressing button 3 will show the current PD Alarm setti...

Страница 14: ...n and the Induced LI flash alarms from button 8 Also cancels the 15 min forced red mode on power up SECTION 4 MAINTENANCE AND TROUBLESHOOTING 4 1 MAINTENANCE No regularly scheduled maintenance is requ...

Страница 15: ...respond with a single quick blink to a button press of 1 on the remote control Yes No Beacon is operational Replace the unit Table 4 4 Troubleshooting Beacon Flashes in Daytime 4 3 BEACON REPAIR PROC...

Страница 16: ...TEGRATED LED BEACON 1350200 5 3 RMA POLICY If any system or part s purchased from Flash Technology needs to be returned for any reason subject to the warranty policy please see the current RMA policy...

Отзывы: