www.flash-butrym.pl
Page 4
The product must be operated at a temperature range of between -5*C and 45*C only.
Protect the product against direct exposure to sunlight or other heat, such as from radiators! If
the product is taken from a cold environment into a warm environment it must only be taken
into operation once it has reached ambient temperature, since the condensation created by the
difference in temperature may destroy the device!
Protect the product against dust! Dust may reduce the protective insulation, which may
cause fatal electric shocks!
The product must be operated at altitudes ranging between 20m below and 3000m
above sea level only!
The product must not be operated during thunder storms; risk of destruction from
surge voltages!
The product must be operated at a minimum distance of 1,5m to lit objects only!
5. Installation
This product can be operated suspended or as a stand-alone system.
Should your lighting effect show any signs of damage, do not install the device! In this
case, have your lighting effect repaired by your specialized dealer. The manufacturer does not
accept responsibility or liability for damage to property or personal injury resulting from an
improperly installation!
As a stand-alone system the device must be installed vertically on an absolute planar,
firm, fireproof, shock- and vibration-free surface. The installation of this lighting effect must
be carried out by trained and professional staff! The installation of this lighting must only be
carried out with the appropriate materials!
The suspended installation of this lighting effect necessitates a suitable suspension
system! The lighting effect must never be fixed swinging freely in the room. No individuals
should linger underneath the lighting effect during suspended installation!
It is a must to install this device with a second independent fixture. Such second
fixture must guarantee in the event of failure of the main fixture that no assembly parts will
fall down. Use the fixture on the undersurface only.
The light effect unit must be attached via two certified hooks and omega bracket to a
tie-bar system. Use the screw threads on the undersurface only.
It must be ensured that an expert inspects the mechanical and safety-relevant
installation prior to the initial operation and following major modifications, prior to the
renewed operation. It must be ensured that an expert inspects the mechanical and safety-
relevant installation at least once a year. It must be ensured that an expert inspects the
mechanical installation and the installation of relevance to safety within the framework of an
acceptance test at least every four years.
The installation fixture must be as such that it can withstand for a period of 60 minutes
10 times the load capacity without harmful deformation.
It is prohibited for any individual to unnecessarily stay or pass beneath the installation
during any type of assembly work.
The light effect unit must be secured by safety arrested cable if fly-mounted. The cable
must withstand 12 times the weight of the light effect unit. Use arrester cables equipped with
quick closing links. The dropping distance must not exceed 20cm. Defect arrester cables or
arrester cables that have already been exposed to stress must not be used.
6. Operation
Controls