Appendix
Page IV Panda 14.000 NE PVK-U S00420 - Chapter F: Appendix
F.4 Troubleshooting
GENERATOR OUTPUT VOLTAGE TOO LOW
For 50Hz versions: less than 200V
For 60Hz versions: less than 100V
Cause
Solution
Generator is overloaded.
Reduce the electrical load. (Switch off load)
Motor is not reaching the rated rpm.
Refer to "motor faults" section.
Defective capacitor(s).
Check capacitors and replace if necessary.
GENERATOR VOLTAGE TOO HIGH (MORE THAN 240V-50Hz / 135V-60Hz)
If the generator is providing excessively high voltage, the following potential causes should be investigated:
Cause
Solution
Over-energizing due to wrong capacitors.
Check capacitors type and replace if necessary.
Measurering voltage on the VCS circuit board is mis-
sing.
Check VCS System, check cable connections.
Motor is running too fast (rpm too high).
Check motor speed with rpm-meter or frequency meter
and adjust to proper speed under "zero" electrical load:
(3120 rpm-50Hz / 3720 rpm-60Hz). Inspect ESC or
VCS Systems if installed.
GENERATOR VOLTAGE FLUCTUATES
Cause
Solution
1. Disturbances on the electrical system/user side.
2. Motor disturbances.
1. Check if electrical load is fluctuating.
2. Refer to section: "Motor runs irregular".
GENERATOR NOT ABLE TO START ELECTRIC MOTOR
Cause
Solution
If the generator is unable supply enough power to start
an electric motor (120V-60Hz or 231V-50Hz), it is
usually because the motor draws too much current
during starting process.
Check the motor's current draw required for starting
(switch to 380V if possible). This could be remedied by
providing stronger capacitors or installing an optional
"Easy Start Booster Set". (See App. G)
Enquire at your nearest Panda dealer or directly at the
manufacturer.
Содержание Panda 14.000 NE PVK-U
Страница 1: ...Generator type Panda 14 000 NE PVK U 400V 50 Hz 12kW Icemaster Fischer Panda...
Страница 28: ...The Panda Generator Page 24 Panda 14 000 NE PVK U S00420 Chapter A The Panda Generator...
Страница 62: ...Generator Failure Page 58 Panda 14 000 NE PVK U S00420 Chapter D Generator Failure...
Страница 92: ...Appendix Page VIII Panda 14 000 NE PVK U S00420 Chapter F Appendix...
Страница 94: ...Measurements Page X Panda 14 000 NE PVK U S00420 Chapter F Appendix F 7 Measurements...
Страница 96: ...Wiring diagram control panel Page XII Panda 14 000 NE PVK U S00420 Chapter F Appendix...