Installation Instructions
Page 68 Panda 14.000 NE PVK-U S00420 - Chapter E: Installation Instructions
Permitted coolant temperatures
The performance of the radiator must be so measured that the coolant temperature of the Panda
generator does not exceed more than 70°C. The coolant intake must be fitted direct to the coolant
pump.
There must be a large amount of water circulating to ensure that the difference in temperature
when compared to the temperature of the water leaving the generator (full load) does not exceed
12°C. The difference may also amount to 17K if a pre-silencer is installed.
The hoses must be so laid out that knots and other obstructions are avoided. If necessary, the
amount of coolant must be measured. As a minimum the following values are necessary:
Essential coolant amounts:
Panda 4500 ............................... min. ca. 10 l/min
Panda 8000 - 9000 ...................approx. 16 to 22 l/min
Panda 12000 - 14000 ..............approx. 24 to 28 l/min
Panda 18 - 24 ........................... approx. 32 to 38 l/min
Panda 30 - 32 ........................... approx. 40 to 45 l/min
Panda 42 - 65 ........................... approx. 50 to 60 l/min
The greater the amount of coolant circulating, the lower the difference in temperature. If the
necessary cooling performance cannot be achieved, the amount circulating can be increased by
adjusting the pulley on the pump and thereby raising the performance.
ATTENTION! The coolant pressure may, however, not exceed 0.7 bar!
Construction and position of the radiator
The radiator can be assembled away from the generator in a well ventilated position. Attention
must be paid that the radiator emission direction is completely free of obstruction. Turbulence is
to be avoided. There is often a clash between the streamline appearance of the chassis and the
technical requirements.
The radiator can be installed (vertically) or (horizontally). Consideration must be given to the fact
that air is drawn in via a fan motor.
The best result is achieved if the radiator is fitted vertically on the vehicle roof.
Содержание Panda 14.000 NE PVK-U
Страница 1: ...Generator type Panda 14 000 NE PVK U 400V 50 Hz 12kW Icemaster Fischer Panda...
Страница 28: ...The Panda Generator Page 24 Panda 14 000 NE PVK U S00420 Chapter A The Panda Generator...
Страница 62: ...Generator Failure Page 58 Panda 14 000 NE PVK U S00420 Chapter D Generator Failure...
Страница 92: ...Appendix Page VIII Panda 14 000 NE PVK U S00420 Chapter F Appendix...
Страница 94: ...Measurements Page X Panda 14 000 NE PVK U S00420 Chapter F Appendix F 7 Measurements...
Страница 96: ...Wiring diagram control panel Page XII Panda 14 000 NE PVK U S00420 Chapter F Appendix...