D.1.5Adjustment of the normal rev limitation
a) Adjusting the lower limitation:
1. Disconnect the plug at the electrical supply line of the actuator.
2. Unclamp the countering nuts with two wrench SW 13.
3. Connect an electrical voltage instrument (voltmeter) with a display range until 300V AC to AC
outlet in the elektrical cabinet.
4. Be sure that no electrical load is adjusted.
5. Start the generator.
6. Decrease the rev of the generator by turning the spindle of the actuator manually until the volt-
meter reach a value of 220V (110V).
7. Both nuts must be screwed tight.
8. Check again if the lower voltage of the generator is limited to min. 220V (110V) without load.
b) Adjusting the upper limitation:
1. Proceed like before and tighten the countering nuts at a voltage of max. 260V (130V) without
load.
2. Check again if the upper voltage of the generator is limited to this value.
01. Adjusting nut for upper rev limitation
02. Adjusting nut for bottom rev limitation
If the adjustment is finished the plug of the actuator must be re-connect for operation.
Re-connect the connections if the electrical supply lines in the AC-control box were also be dis-
connected.
01
02
Содержание Panda 14.000 NE PVK-U
Страница 1: ...Generator type Panda 14 000 NE PVK U 400V 50 Hz 12kW Icemaster Fischer Panda...
Страница 28: ...The Panda Generator Page 24 Panda 14 000 NE PVK U S00420 Chapter A The Panda Generator...
Страница 62: ...Generator Failure Page 58 Panda 14 000 NE PVK U S00420 Chapter D Generator Failure...
Страница 92: ...Appendix Page VIII Panda 14 000 NE PVK U S00420 Chapter F Appendix...
Страница 94: ...Measurements Page X Panda 14 000 NE PVK U S00420 Chapter F Appendix F 7 Measurements...
Страница 96: ...Wiring diagram control panel Page XII Panda 14 000 NE PVK U S00420 Chapter F Appendix...