Maintenance Instructions
Panda 14.000 NE PVK-U S00420 - Chapter C: Maintenance Instructions Page 37
Pour in coolant through the cooling water
filler cap. The coolant flows in very slow.
If it is to be recognized that the cooling water level does not sag any longer (with cold cooling
water the cooling water level must cover the sheet metal in the exhaust elbow union), close the
de-aerating screws and start the generator. Run the generator to maximally 60. Switch off gene-
rator.
Open the cooling water filler neck again
and also the de-aerating screws at the
same time.
Fill in again cooling water.
Repeat this procedure several times.
The generator can be started for 5 minutes, if there is no change. De-aerating must be then
repeated two or three times.
To be sure that the coolant circulates it is very important that the hose pipe away from the genset
also gets warm. After a short time the radiator and the reverse-flow pipe from the radiator to the
genset also get warm.
Please wait until the temperatures raise more and check if the fan will activate.
It makes sense to, once again, repeat the de-aerating procedure after a few days, in order to
ensure that remaining air bubbles have been finally removed.
Содержание Panda 14.000 NE PVK-U
Страница 1: ...Generator type Panda 14 000 NE PVK U 400V 50 Hz 12kW Icemaster Fischer Panda...
Страница 28: ...The Panda Generator Page 24 Panda 14 000 NE PVK U S00420 Chapter A The Panda Generator...
Страница 62: ...Generator Failure Page 58 Panda 14 000 NE PVK U S00420 Chapter D Generator Failure...
Страница 92: ...Appendix Page VIII Panda 14 000 NE PVK U S00420 Chapter F Appendix...
Страница 94: ...Measurements Page X Panda 14 000 NE PVK U S00420 Chapter F Appendix F 7 Measurements...
Страница 96: ...Wiring diagram control panel Page XII Panda 14 000 NE PVK U S00420 Chapter F Appendix...