![Fischer Panda 45i pms Скачать руководство пользователя страница 59](http://html1.mh-extra.com/html/fischer-panda/45i-pms/45i-pms_user-manual_2294277059.webp)
Installation Instructions
8.10.14
Kapitel/Chapter 6: Installation Instructions - Seite/Page 59
Attention!: Disconnect all load.
Disconnect all load during the work at the generator to avoid
damages at the load.
6.2
Place of installation
6.2.1 Preliminary remark
• There must be sufficient fresh air supply for the combustion air.
• It has to be ensured that the cooling air supply from underneath or sidewise is sufficient.
• During operation the sea cock has to be opened.
• The generator may only be opened by a technical trained person.
• The generator may only be operated by a trained person.
6.2.2 Preparing the base - placement
Since Panda generators have extremely compact dimensions, they can be installed in tight locations. Attempts are
sometimes made to install them in almost inaccessible places. Please consider that even almost maintenance-free
machinery must still remain accessible at least at the front (drive belt, water pump) and the service-side (actuator,
dipstick). Please also note that in spite of the automatic oil-pressure sensor it is still essential that the oil level has to
be checked regularly.
The generator should not be placed in the proximity of light walls or floors, which can have resonance vibrations
because of airborne sounds. If this should be unavoidable, then it is recommended that this surface is lined with
1 mm lead foil, which will change the mass and the vibration behaviour.
You should avoid fixing the generator on a slippery surface with little mass (i.e. plywood). This acts as an amplifier of
airborne sounds in the most unreasonable case. An improvement can be achieved by reinforcing these surfaces
with ribs. In addition, the breakthroughs, which interrupt these surfaces, should be sawed off. The lining of the sur-
rounding walls with a heavy layer (i.e lead) and foam additionally improve the conditions.
As the generator sucks in its combustion air via several drill holes in the capsule base, the capsule base must be
installed with sufficient space to the basement so that the air supply is guaranteed (at least 12 mm/½“)
The generator sucks its air from the surrounding engine room. Therefore it must be ensured that sufficient ventilation
openings are present, so that the generator cannot overheat.
High temperature of the intake air declines the power of the generator and increases the coolant temperature. Air
temperatures of more than 40 °C reduce the power by 2 % per temperature rise of 5 °C. In order to keep these
effects as small as possible, the temperature in the engine room should not be higher than 15 °C in relation to the
outside temperature.
Содержание 45i pms
Страница 3: ...8 10 14 Kapitel Chapter A Seite Page 3...
Страница 4: ...Seite Page 4 Kaptitel Chapter A 8 10 14...
Страница 12: ...Seite Page 12 Kaptitel Chapter 1 8 10 14...
Страница 148: ...Generator Failure Seite Page 148 Kaptitel Chapter 8 Generator Failure 8 10 14...
Страница 160: ...Tables Seite Page 160 Kaptitel Chapter 9 Tables 8 10 14...
Страница 176: ...Inverter Panda PMGi 45 Seite Page 176 Kaptitel Chapter 10 Inverter Panda PMGi 45 8 10 14...
Страница 204: ...Seite Page 204 Kapitel Chapter 3 Installation 8 10 14 Leere Seite Intentionally blank Installation...
Страница 206: ...Seite Page 206 Kapitel Chapter 4 Maintenance 8 10 14 Leere Seite Intentionally blank Maintenance...
Страница 212: ...Seite Page 212 Kapitel Chapter 6 Annex 8 10 14 Leere Seite Intentionally blank Annex...