Optional Equipment
(for qualified installers only)
4 1
Travis Industries
9 3 5 0 8 1 1 6
0 3 1 0 0 0
6
Make the gas line connection, bleed the gas line (if applicable), start the heater and thoroughly leak-
test all gas connections and the gas control valve. Check the pilot. Adjust if necessary.
WARNING:
When lighting or re-lighting the pilot, the glass must be removed (see
page 24).
Standard
Screwdriver
The pilot flame must contact the thermocouple and
thermopile (see the illustration below). Adjust the pilot up or
down as necessary.
To adjust the pilot flame, turn this screw (NOTE: if totally
unscrewed gas will come out of this port). Clockwise
lowers the flame while counter-clockwise raises it.
7
Install the log set (see page 25).
8
Replace the glass and face (see page 24) and face (page 13 or 14).
Fireback (Part # 98500675)
!
Install the fireback prior to installing the log set.
Locate the four dimples on the firebox walls (two
on the back, one on each side). Use a power drill
with a 1/4” socket and the included self-drilling
screws to pre-drill (and thread) the holes. Do not
strip the threads by over-torquing the screws.
Remove the screws.
NOTE: on earlier models these holes are not
present - they will require placement and drilling -
see the compatibility note above.
Install the fireback floor pieces at the front of the firebox.
You may need to lift up on the grate at the front of the burner
to install the floor pieces. Tuck the front brick stop between
the front of the fireback and the front of the firebox - the
brick stop prevents the floor fireback from contacting
the glass.
Place the rear fireback so it is centered against
the rear wall of the firebox. Secure with two
fireback clips and the screws.
Place the side firebacks in place. Secure
with a fireback clip and screw. Repeat
for the opposite side.