10
Installation
(for qualified installers only)
Travis Industries
9 3 5 0 8 1 1 6
0 3 1 0 0 0
Facing Requirements
•
Drywall may be butted up to the drywall standoff.
N O T E
:
Drywall or other combustibles may not be placed over the drywall standoff.
N O T E
:
No drywall or other combustible may protrude farther than 3/4" in front of the drywall standoff.
Any combustible material that protrudes 3/4" or more from the drywall standoff must meet the
mantel clearance (if located above the fireplace) or sidewall clearance (if located to the side of
the fireplace – see the illustration below).
HINT
:
Holes are provided in the drywall standoff to attach the standoff to the framing members. This
stabilizes the standoff and allows the drywall to be anchored to the framing members.
Maximum 3/4”
Drywall
Use the holes in the drywall standoff to
secure the standoff to the framing.
Drywall
Standoff
Framing
Min. 8-1/2” Clearance to Combustibles
(from edge of glass frame)
N O T E
:
Mask off the front of the fireplace to keep drywall dust from entering the fireplace. These
particles, when heated, may cause odors or cause other problems.