Installation
(for qualified installers only)
7
Travis Industries
9 3 5 0 8 1 1 6
0 3 1 0 0 0
Fireplace Placement Requirements
Minimum Framing Dimensions
The 1/2” stand-offs along the sides and back, and the 2-1/2" stand-offs on top of the fireplace
separate the fireplace from combustible materials (e.g.: combustible framing members, plywood,
sheetrock, paper-backed insulation). The stand-offs may contact the framing members but no material
may be placed between the stand-offs.
This fireplace may be placed in a bedroom. Please be aware of the large amount of heat this appliance
produces when determining a location.
AAAA
AAAA
AA
AAAA
AAAA
AA
A
A
AA
AA
AA
A
AA
AA
AA
AA
AAA
AAA
AAA
AA
A
A
A
AA
Gas line (3/8" M.P.T. or 1/2" F.P.T.)
should be routed 4-1/2" behind the
framing opening and 3-1/4" above the
base of the fireplace on the right side
(see "Gas Line Connection" for
details).
39-7/8"
16-7/8"
32"
Route the electrical line to a
position at the left front of
the fireplace.
If using a remote
control or thermostat,
route the wire to a
location near the gas
line (include an extra 3'
length for hookup).
With an elbow directly off the top of the
fireplace, the vent is centerd 36" above
the base of the fireplace.
The fireplace enclosure
must not be less than
42" above the base of
the fireplace.
42" Min.
Wall Thimble (required when
passing through a wall)
•
Fireplace must be installed on a level surface capable of supporting the fireplace and vent
•
Fireplace must be placed directly on wood or non-combustible surface (not on linoleum or carpet)
•
Due to the high temperature of the fireplace, it should be located out of traffic and away from furniture
and draperies.
Clearances
•
When installed, walls in front of the fireplace must be a minimum 8-1/2" to the side of the fireplace
facing (drywall standoff).
•
Fireplace must be placed so that no combustibles are within, or can swing within 36" of the front of the
fireplace (e.g. drapes, doors)
•
Fireplace must be placed so the vents below and above the glass do not become blocked