Hearth Requirements
•
The fireplace must be placed on a wood or non-combustible sub-floor.
•
No hearth is required.
N O T E
:
Carpeting or other floor covering (e.g. linoleum, wood flooring) must not protrude 3/4" above
the base of the fireplace. The fireplace must be raised to accommodate any flooring thicker
than 3/4".
HINT
:
We strongly suggest using a tile or non-combustible hearth in front of the fireplace. This
protects the area in front of the fireplace from heat dis-coloration or off-gassing. Travis
Industries can not be responsible for floor discoloration in front of the fireplace.
HINT
:
If using a 36-DV Face, please be aware that a 1-1/8" gap will appear below the face. We
suggest a non-combustible hearth in front of the face to conceal this area.
Maximum 3/4”
Carpeting or other floor covering
(e.g. linoleum, wood flooring) must
not protrude 3/4" above the base of
the fireplace. The fireplace must be
raised to accommodate any flooring
thicker than 3/4".