Kompact RU Installation Version 14/4/14
5
If the heater is to be installed onto a SOLID concrete floor protector (hearth) that
has no heat sensitive materials in its construction it must meet the following
MINIMIUM dimension as marked A & B from Diagram 1:
A 300mm from breast of fire to outer edge of concrete floor protector (hearth)
B 30mm from heat sensitive floor to upper edge of concrete floor protector
(hearth)
The minimum width of floor protector must be 820mm and/or 410mm from the
centre of the heater.
2B FLOOR PROTECTOR REQUIREMENTS
HEAT SENSITIVE FLOORS
An Insulated Floor
Protector (Hearth) must
consist of a minimum of
20mm of Insulation
board (Micore 160,
Supalux, Promatech H,
Eterpan LD or product of
similar thermal resistance)
and tiles/slate or similar
with sealed joints on top
surface to protect from
spilt ash/embers.
Dimensions A & B from above diagram must meet the following schedule:
B HEIGHT (mm) A FROM FIRE BREAST
Level Ømm
500mm
30mm
376mm
HEAT SENSITIVE FLOOR
INSULATED FLOOR PROTECTOR
FIRE BREAST / WALL
A
FASCIA
B
Diagram 2
Содержание kompact ag
Страница 13: ...Kompact RU Installation Version 14 4 14 13 Diagram 9 ...
Страница 16: ...Kompact RU Installation Version 14 4 14 16 Diagram 12 ...
Страница 19: ...Kompact RU Installation Version 14 4 14 19 Diagram 15 ...
Страница 29: ...Kompact RU Installation Version 14 4 14 29 KOMPACT WITH ATHENA FASCIA ...
Страница 31: ...Kompact RU Installation Version 14 4 14 31 KOMPACT WITH DECO FASCIA ...
Страница 33: ...Kompact RU Installation Version 14 4 14 33 KOMPACT WITH FORTE FASCIA ...
Страница 35: ...Kompact RU Installation Version 14 4 14 35 KOMPACT WITH 760MM PLAZA FASCIA 760mm Fascia Masonry ONLY 780 ...
Страница 38: ...Kompact RU Installation Version 14 4 14 38 KOMPACT WITH SERENITY 4 SIDED FASCIA ...