![Finn HydroSeeder T120GN Скачать руководство пользователя страница 17](http://html1.mh-extra.com/html/finn/hydroseeder-t120gn/hydroseeder-t120gn_operators-manual_2290165017.webp)
11
3. EXTENSION HOSE OR HOSE REEL THROUGH REMOTE PORT:
Flow is through recirculation with no flow through closed discharge valve (Figure 3). Flow through extension
hose is controlled by engaging and disengaging slurry pump clutch, or by remote valve at end of hose. Open
recirculation valve allows flow back into tank.
DANGER:
Recirculation valve must be open and material flowing back into
tank when using a remote valve. A closed or plugged recircu
-
lation line will cause extreme heat resulting in damage and/or
bodily injury.
Figure 4- Discharge Through Boom or Extension Hose Through Boom
Figure 5 - Discharge Through Extension Hose or Hose Reel Through Remote Port
FLOW
OPEN
CLOSED
CLOSED
FLOW
FLOW
OPEN
Содержание HydroSeeder T120GN