7
CAUTION:
Your FINN HydroSeeder
®
should be mounted by a qualified truck
body installer.
When mounting the T120 HydroSeeder
®
to the truck, any one of the following methods of mounting is accept-
able:
A. Bolt the HydroSeeder
®
directly to the truck bed. Installer must insure that the bed as well as the bed
to truck and HydroSeeder
®
to bed connections are adequate for the full load weights that are shown on
page 6.
B. Mount the HydroSeeder
®
to the truck frame.
NOTE:
The T120 HydroSeeder® has mounting legs that are 44" (111.76 cm)
across and therefore requires an adapter frame or chassis bed of
adequate strength to mount the truck's 34" (86.36 cm) wide rails.
IMPORTANT:
Mounting the HydroSeeder® to the truck must allow for tire clearance
as well as frame twist. Place hard wood spacers along the length of
truck rails or use Finn spring mounting kit (#011562) or equivalent.
C. Place chains over the HydroSeeder
®
and around truck bed and secure with binders. Secure the
HydroSeeder
®
with blocks tied to the truck bed.
IMPORTANT:
When using a truck with a tilt bed be sure to chain the truck bed down
to prevent the bed from being accidentally hoisted.
ATTACHMENTS:
1. Extension hoses for reaching remote areas are available in 50 ft. (15m) lengths. All connections are
camlock quick operating fittings. The hose is connected to the end of the discharge boom in place of a
nozzle. The nozzle is connected to the end of the hose and controlled by the person on the ground. The
flow is controlled by a second person on the HydroSeeder
®
. This allows for a full pressure and volume
operation.
2. For lower pressure applications, or for close up work, i.e. around buildings, the remote valve attachment
can be used. The attachment includes semi-rigid hose with quick disconnect fittings along with a hand
held valve which fits the end of the hose and accepts the standard nozzle assemblies. The hose is con-
nected to the outlet on the discharge pipe above the pump. The machine is run at 1/2 to 3/4 throttle and
material is applied where desired.
DANGER:
The recirculation valve must be open when using a remote valve.
If valve is not open, extreme heat will occur resulting in damage
and/or bodily injury.