Vacuum Parameters
Parameter
Default
Min
÷
Max
Description
Vacuum - Vac.Motor
Nominal Current # Amp.
25
10
÷
40
Vacuum Motor Rated current; with T Nom manages
the amperometric protection (alarm + stop brush mo-
tor).
Vacuum - Vac.Motor
Overload Time # sec.
30
1
÷
60
Vacuum Motor Rated Timer; with I Nom manages the
amperometric protection (alarm + stop brush motor).
Vacuum - Vac.Motor
Switch-On Delay # sec.
0.2
0.1
÷
5.0
Brush Motor Switch on Delay when the traction pedal
is pressed.
Vacuum - Vac.Motor
Switch-Off1 Delay # sec.
10
1
÷
300
(Off function) Brush Motor Switch off Delay when the
traction pedal is released.
Vacuum - Vac.Motor
Reset Delay # sec.
300
1
÷
300
Reset Timing from amperometric protection.
Vacuum - Vac.Motor
Vacuum Noise Level 1 #
V
17
12
÷
24
Motor working Voltage, Level 1.
Vacuum - Vac.Motor
Vacuum Noise Level 2 #
V
20
12
÷
24
Motor working Voltage, Level 2.
Vacuum - Vac.Motor
Vacuum Noise Level 3 #
V
24
12
÷
24
Motor working Voltage, Level 3.
51
Содержание 109070
Страница 1: ...SERVICE MANUAL BMG Version AA Date May 9 2019 Document Number 10088000...
Страница 4: ...Part I Product Introduction 4...
Страница 10: ...1 7 1 BMG 56 10...
Страница 11: ...1 7 2 BMG 65 11...
Страница 12: ...1 7 3 BMG 50 BTO 12...
Страница 16: ...Part II Anomalies Resolution Guide 16...
Страница 24: ...Part III Functional Groups 24...
Страница 26: ...3 2 Location of Electrical Components 26...
Страница 60: ...4 6 Related electrical circuit 4 6 1 BMG 56 60...
Страница 68: ...5 6 Related electrical circuit 5 6 1 BMG 65 68...
Страница 72: ...5 8 3 Brush Deck Actuator see section 4 8 3 at page 63 72...
Страница 76: ...6 6 Related electrical circuit 6 6 1 BMG 50 BTO 76...
Страница 80: ...Chapter 7 Vacuum Unit 7 1 Location on machine The vacuum unit is located in central rear position 80...
Страница 84: ...7 6 Related electrical circuit 84...
Страница 90: ...8 5 Related electrical circuit 90...
Страница 98: ...9 5 Related electrical circuit 98...