3.7.3
Checking the acid batteries
TEST OF DENSITY OF ELECTROLYTE
1. Do not add water
2. Using the electrolyte, rinse the density meter at least 3 times before taking a sample
3. Fill the densimeter so that the oscillating part of it is completely supported by the liquid
4. Repeat the operation on all cells
5. Compare the readings of the various cells and check the charge condition of the batteries with the table
The readings should all be at the value of the following table
±
0.007. If any reading is lower, proceed as follows:
1. Check the battery voltage
2. Fully charge the battery
3. Repeat the electrolyte density reading
If the measured density is even lower, an equalization cycle can be attempted (if the charger allows it). If in
any case the measured density of all or some of the cells is less than the value 1.227 it means that:
1. The battery is probably at the end of its life
2. The battery was left without charge for too long
3. Part of the electrolyte was lost during a refill
4. A cell is defective or has leaks
5. The addition of water was excessive just before the test
Reported density
Charge %
16
°
C/61
°
F
21
°
C/70
°
F
27
°
C/80
°
F
33
°
C/91
°
F
100
1,269
1,273
1,277
1,281
90
1,250
1,254
1,258
1,262
80
1,230
1,234
1,238
1,242
70
1,209
1,213
1,217
1,221
60
1,187
1,191
1,195
1,199
50
1,164
1,168
1,172
1,176
40
1,140
1,144
1,148
1,152
30
1,116
1,120
1,124
1,128
20
1,090
1,094
1,098
1,102
10
1,065
1,069
1,073
1,077
55
Содержание 109070
Страница 1: ...SERVICE MANUAL BMG Version AA Date May 9 2019 Document Number 10088000...
Страница 4: ...Part I Product Introduction 4...
Страница 10: ...1 7 1 BMG 56 10...
Страница 11: ...1 7 2 BMG 65 11...
Страница 12: ...1 7 3 BMG 50 BTO 12...
Страница 16: ...Part II Anomalies Resolution Guide 16...
Страница 24: ...Part III Functional Groups 24...
Страница 26: ...3 2 Location of Electrical Components 26...
Страница 60: ...4 6 Related electrical circuit 4 6 1 BMG 56 60...
Страница 68: ...5 6 Related electrical circuit 5 6 1 BMG 65 68...
Страница 72: ...5 8 3 Brush Deck Actuator see section 4 8 3 at page 63 72...
Страница 76: ...6 6 Related electrical circuit 6 6 1 BMG 50 BTO 76...
Страница 80: ...Chapter 7 Vacuum Unit 7 1 Location on machine The vacuum unit is located in central rear position 80...
Страница 84: ...7 6 Related electrical circuit 84...
Страница 90: ...8 5 Related electrical circuit 90...
Страница 98: ...9 5 Related electrical circuit 98...