Problem
Inspection
Status
Cause
Solution
The engine is stopping, it is
diffi cult to start or cannot be
started at all
Sparks on the
spark plug
electrodes
No spark
Incorrect
distance of
the electrodes
(gap)
Set the gap to
0.6 - 0.7 mm
Dirty
electrodes
Clean out or replace
Electrodes are
soiled by fuel
Clean out or replace
Damaged
spark plug
Replace the spark
plug
The motor runs but keeps
stopping and does not have
the correct acceleration
Air fi lter
Dirty air fi lter
Standard wear
and tear
Clean out or replace
Fuel fi lter
Dirty fuel fi lter
Dirt or deposits
in the fuel
Replace
Fuel valve
Clogged fuel valve
Dirt or deposits
in the fuel
Clean out or replace
Spark plug
Dirty or worn out
spark plug
Standard wear
and tear
Clean out, adjust or
replace
Carburettor
Incorrectly
adjusted
Vibrations
Adjust
Cooling system
High temperature
Long term
use in a dirty
or dusty
environment
Clean
Suppressor
Cracked, soiled or
perforated board
Standard wear
and tear
Replace
The engine is not driving the
power tool
Not available
Not available
Internal engine
fault
Request a repair at
an authorised service
centre