27
Sample 2
TIME 15:31:54
DATE 14.04.2009
NET 500.0kg
UNIT.W 599.949 g
COUNT 833PCS
8.2 Custom Print Output Format
26
27
Maximum 15 lines can be entered.
16 va 2 commands (
Cr LF and End
) are available for custom print
output format. Refer to the Below
Print Output Format Variants Table
for
more detail.
8.2.1 To Edit Custom Print Output Format
Follow the below steps to create custom printout.
a. Go to internal function and select the desired function number to edit,
b. Select CUSTOM and press
[M+]
,
c. Scale displays
Line 1
and the last variant or command (see
8.2.2
for
details) stored,
d. Press
[M+]
to confirm or select other variant or command by press
[FUNC]
or
[UNIT]
. Then press
[M+]
to confirm and save,
e. Scale displays
Line 2
and the last variant or command stored,
f.
Repeat steps
d
and
e
for other lines,
g. (In case, number of lines to be printed is less than 15 lines) To finish
editing, select command
End
,
then pres
[M+]
to confirm.
h. Scale returns to and displays the current internal function number,
i.
If required, repeat steps
a
to
h
to create and edit custom printout
format for other functions.
Notes: -
1.
Disregarding the total number of lines, the last line must be =
End
.
26
When F18 is either set to
MODE 3
27
Scale does not support DTR (data of offline detection)