14.2 Define when a Transaction Data is saved to Alibi memory
16
It is important
to define first the timing at when the data of a transaction is saved to Alibi memory during system setup. To do so, go to F71 (supervisor password
may be needed) and select the preferred parameter. 6 parameters are available.
a.
Off = No transaction will be recorded.
b.
Auto 1 = All stable weight (starts from gross zero or minus) is recorded by system automatically.
c.
Auto 2 = The highest stable weight value of a weighing process is recorded by system automatically (when all loads are removed and gross weight
returns to zero or minus).
d.
Auto 3 = The last stable weight value of a weighing process is recorded by system automatically (when all loads are removed and gross weight returns
to zero or minus).
e.
Manual = Transaction is recorded by system automatically when
[Print/M+]
is pressed.
f.
ACC = Transaction is recorded by system automatically when a new accumulated data is created automatically or manually.
16
Auto 1 ~ 3 do not support PA.