38
15.3.1 Print output format variants table
Symbol
Description
End
Edit finished
Cr LF
Insert one blank row
dAtE
Date of printing
time
Time of print
nEt
Net weight
tArE
Tare weight
GroSS
Gross weight
Unit
Average piece weight
Count
Number of piece
H rEF
HI limit
L rEF
LO limit
Ani
Weight Hold (Animal weighing)
Ch rES
Comparison result
trAnS
Transaction sequent number
(if this transaction is accumulated to memory)
ACC
Total accumulated weight
(when accumulation function is in effect)
SiGn
Signature
P Code
Product code
Peak
Peak hold value
Id
Machine ID
GrouP
Machine group number
oPCodE
Operator number
C CodE
Customer code
15.3.2 To edit custom Lab 2 print output format
Follow the below steps to create custom printout.
a. Go to internal function and select the desired function number to edit,
b. Select
CUSTOM
and press
[Print/M+]
,
c. This instrument displays
Line 1
and the last variant or command (see
15.3.1
for details) stored,
d. Press
[Print/M+]
to confirm or select other variant or command by press
[Func]
or
[Unit]
. Then press
[Print/M+]
to confirm and save,
e. This instrument displays
Line 2
and the last variant or command stored,
f.
Repeat steps
d
and
e
for other lines,
g. To finish editing, select command
End
,
then press
[Print/M+]
to confirm.
h. This instrument returns to and displays the current internal function number,
i.
If required, repeat steps
a
to
h
to
create and edit custom printout format for other modes.