F21
Lab 2 Weight Function Output Print
Format
** STD
CUSTOM
F22
Lab 2 Counting Function Output Print
Format
** STD
CUSTOM
F23
Reserved.
F24
Lab 2 Animal Functions Output Print
Format
** STD
CUSTOM
F25
Reserved.
F26
Near Zero
Weight Value
** 000000
Near Zero value is useful for dynamic weight check applications to bypass unnecessary LO alarm during uploading and unloading process. Notes: -
Value entered valid only when Check function is activated.
Near zero weight value can be any value between 20d and LO limit.
Any near zero value which less than 20d will be ignored. Instrument will deem 20d as minimum near zero weight value.
The HI LO comparison remains non-activated when weight reading is less than the near zero value entered here.
F27
Reserved.
F28
Ask for Operator Number when Power on
Yes
** No
Yes: - Instrument will ask for operator number during countdown process when power on. Enter 4-digit operator number or press
[CE/x10]
to skip operator number when being
asked.
No: - Instrument will not ask for operation number.
F29
Read Calibration and parameter set counts.
O (Parameter set count): - shows total times that the important parameters (F80~F88) has been altered.
C (Calibration count): - shows total times of calibration.
F30
Allow Letters and Symbols for Customer
& Product Code Manual Entry
On
** Off
F31
Auto Power Saving
Off
** On
Off = Auto Power Saving disable.
On = Display brightness will switch to minimum when weight remains unchanged for 30 seconds.
Note:
- Auto Power Saving will be disabled when an energized power adaptor is plugged in.
F32
Optical Key Assignment
** Off (Key disable)
[Zero]
[Tare]
[Print / M+]