6.7.1 Automatic Accumulation
22
Automatically accumulation is activated when Auto Accumulation is set to
On
in Auto 1, Auto 2, Auto 3 or Manual
mode is selected in F16 and/or F17.
Under the automatic accumulation mode, corresponding results will be accumulated automatically.
6.7.2 Manual Accumulation
23
Manual Accumulation is activated when scanner, PC or CMD mode is selected for
both
F16 and/or F17.
Under the Manual Accumulation mode, press
[Print/M+]
to accumulate the current value to memory.
6.7.3 When data is accumulated to memory
24
25
26
1.
When a result is accumulated to memory, this instrument displays “
n____x
”.
M+ Indicator
appears to
indicate that memory contains stored data. “x” means the total number of transactions accumulated to
memory.
2.
This instrument returns to normal display status after 2 seconds.
6.7.4 Memory recall and clearance
Accumulation data will be stored in memory and will not be erased by normal power off (by pressing the
[ON/Off]
key) process. But changing weight unit or to another working mode will automatically erase accumulation data
stored.
Follow below procedures to recall and clear accumulation data.
1.
Press
[MR]
to recall total accumulated weight.
2.
Instrument flashes between “A____Y” (Y means the number of transactions accumulated) and total
accumulated result.
3.
At this point: -
•
Press
[Zero]
to quit, or
•
Press
[CE/x10]
to clear memory. After
[CE/x10]
is pressed, instrument display Clear and M+
Indicator disappears to indicate all no data is stored in memory.
4.
Press
[MR]
to recall total accumulated weight
.
5.
Instrument flashes between “
A____Y”
(
Y
means the number of transactions accumulated) and total
accumulated result.
6.
At this point: -
•
Press
[Zero]
to quit, or
•
Press
[CE/x10]
to clear memory. After
[CE/x10]
is pressed, instrument display Clear and M+
Indicator disappears to indicate all no data is stored in memory.
6.8 Extended Display Mode
27
When F68 is set to OIML or NTEP, by pressing
[CE/x10]
the weighing resolution will be temporary (for 5 seconds)
changed to 10 times finer. Display keeps flashing when instrument is displaying the extended result.
22
Refer to
5.5.4
for setting details.
23
Refer to
5.5.3
for setting details.
24
Memory Accumulation Function accumulated weight results only.
25
When F16 and F17 is set to mode Auto1~3, unstable result or result which is less than 20d (or 20d
1
for dual weighing
range/interval mode) will not be accumulated to memory.
26
All data stored will be erased when weight unit or working mode is changed.
27
When F68 = OIML or NTEP.