6.4.2 Auto Tare (F12)
13
3 parameters are available: - Off. Auto and Contin
Off: - Auto tare disable.
Auto: - instrument will assume the first stable weight (≥ 20d or
20d1) applied is a container and will then tare off the weight of it
automatically. When container is removed and gross weight result
is zero, tare effect will be cancelled automatically.
Contin (continuous auto tare); - all stable weight (≥ 20d or 20d1)
applied will be tare off automatically. When all loads are removed
and gross weight result is zero, tare effect will be cancelled
automatically.
6.4.3 Repetitive Tare (F13)
14
F13 are set to OFF, this instrument does not permit multiple tare operation.
Tare effect can only be cancelled when container is removed and gross weight
is zero.
When F13 is set to ON, this instrument will permit multiple tare operation
provided that
both
of the below requirements are met: -
a.
The tare operation does not permit a reduction of the value of the
tare, and
b.
The tare effect can only be cancelled when there is no load on the
platform.
6.4.4 Preset Tare (F63)
15
16
Preset tare allows a pre-determined tare weight value can be entered via
numeric keys.
During weighing mode and when weight is zero, press
[0]
, then enter the pre-
determined tare weight value though numeric keys then press
[Print/M+]
to
13
Set F12 = ON to enable Auto Tare Function
14
Set F13 = ON to enable Repeated Tare Function.
15
Set F63 = ON to enable Preset Tare Function. Some countries may not consider preset
tare function as a legal for trade function. Contact your dealer for more information.
16
Set also F12 to Off.