46
Piece Count mode = piece value.
Auto Tare Accumulation mode = weight value.
12.1 Set LO& HI Limit
Follow the below steps to set LO and HI Limit.
1.
During desired operation mode, press
[Check]
.
2.
Instrument displays Low followed by a 6-digital value. Enter the LO
limit through numeric keys or press
[CE/x10]
to set LO limit to zero
then press
[Print/M+]
to save.
3.
Instrument displays HIGH followed by a 6-digital value. Enter the HI
limit through numeric keys or press
[CE/x10]
to set LO limit to zero
then press
[Print/M+]
to save.
4.
Check Mode is now enabled. The check result is shown by one of the
Light Bar
42
.
12.2 Hints for Entering LO and HI Limits
a.
For normal comparison, set both LO and HI Limit.
b.
To check only if result is lower than or equal to LO (result ≤ LO),
set HI Limit = 0.
c.
To check only if result is higher than or equal to HI (result ≥ HI),
set LO Limit = 0.
d.
To check if result is equal to a specified value, set both HI Limit
and LO Limit = the specified value.
12.3 To Cancel Check Function
To cancel check function, press
[CE/x10]
on point
2
and
3
of
12.1
.
12.4 Tri-color Check Result Light Bar
This instrument is equipped with a tri-color light bar. The tri-colors are: -
Yellow to represent LO status.
Green to represent OK status.
Red to represent HI status.
42
Yellow = Lo; Green = OK; Red = Hi.