Bit Number
Functio
n
Add
ress
Name
R/W
7 6 5 4 3 2 1 0
Logic
Defa
ult
Description
D2h
BAT_DC
H_
CONT
R/W
RES[7:2]
D
C
H
G
2
D
C
H
G
1
0: Not
discharge
1: Discharge
-
The discharge
battery can be
selected one of the
batteries can be
discharged.
D3h
BAT_WA
R_
ABS
R/W
DATA[15:0] *1
-
0x00
00
Absolute capacity
battery Warning
detection point
0x0000-0xffff
(mWh)
D5h
BAT_LO
W_
ABS
R/W
DATA[15:0] *1
-
0x00
00
Absolute capacity
battery Low
detection point
0x0000-0xffff
(mWh)
D7h
BAT_WA
R_
REL
R/W
DATA [7:0]
-
0x10
Relative capacity
battery Warning
detection point
00-C8h (0-100%
step 0.5%)
D8h
BAT_LO
W_
REL
R/W
DATA [7:0]
-
0x06
Relative capacity
battery Low
detection point
00-C8h (0-100%
step 0.5%)
D9h
*3
FULL_D
ATA
R/W
DATA [7:0]
-
0xbe
Full charge cancel
point
00-C8h (0-100%
step 0.5%)
Dah
CC_CUR
_
DATA
R
DATA [7:0]
-
0x00
Battery charging
current setting
0x01-0xff (0.02-
5.10A step 0.02A)
0x00 Depends
on the battery
This register is
“
read only
”
, to
change the value,
use the register in
PMU registers area.