![FIC MB05W Скачать руководство пользователя страница 59](http://html1.mh-extra.com/html/fic/mb05w/mb05w_service-manual_2286939059.webp)
FIC MB05W Service Manual
FIC MB05 Service Manual
1-59
Regist
er
Bit Number
Functi
on
Addres
s
Name
R/W
7 6 5 4 3 2 1 0
Logi
c
Defaul
t
Description
18h
*3
OEM
Inform
ation
R(/W)
DATA
[15:8]
*1
All bits
are 0
Vender
[7:0]
-
0xffff
Vender [7:0] This code
depends on battery data
format.
And the following name
should be described in the
ASL with the same
character code.
In the future, these codes
will be added.
0:
“
MoliEnergy
”
1:
“
Panasonic
”
2:
“”
(SANYO
does not agree the vender
name
display)
3:
“
TBCL
”
(Toshiba)
4:
“
Sony
”
1Ah
*3
Battery
State
R
(/W)
DATA[15:3]
*1
All bits are 0
C
R
I
T
C
H
G
D
C
H
G
-
-
DCHG=1:
CHG =1:
CRIT =1:
The battery is
discharged
The battery is
charged
The battery is
critical
(Empty)
1Ch
*3
Battery
Presen
t rate
R
(/W)
DATA[15:0] *1
-
0xffff
0x0000-0xfffe(mW)
0xffff: Unknown
1Eh
*3
Battery
Remai
ning
Capaci
ty
R
(/W)
DATA[15:0] *1
-
0xffff
0x0000-0xfffe(mWh)
0xffff: Unknown
1
st
Battery
[ _BST
]
20h
*3
Battery
present
Voltag
e
R
(/W)
DATA[15:0] *1
-
0xffff
0x0000-0xfffe(mV)
0xffff: Unknown
1
st
Battery
[ _BTP
]
22h
Battery
Trip
Point
R/W
DATA[15:0] *1
-
0x000
0
0x0000: Clear the trip
point
0x0001-0xffff(mWh)
2
nd
Battery
[ _BIF ]
24h
to
3Ch
*3
*2
*2
*2
*2
*2
*2
2
nd
3Eh
*2
*2
*2
*2
*2
*2
PDF created with FinePrint pdfFactory trial version