Festo — SFAB-...-PNLK — 2022-08
IO-Link interface description
29
8.5
Smart sensor profile parameters
Index
Sub Index Access
1)
Name
Value
Format
0x000D
(13)
0x00
R
Profile Characteristics
0x0011, 0x0031,
0x8101, 0x8102
ArrayT of
UInte-
gerT16
0x01
Device Profile ID
0x0011: Measuring and
switching sensor, 2-
channel (SSP 4.1.2)
UInte-
gerT16
0x02
0x0031: Firmware
update
0x03
Function Class ID
0x8101: Extended iden-
tification/localisation
0x04
Function Class ID
0x8102: Product URI
0x000E
(14)
0x00
R
PD Input Descriptor
0x03, 0x10, 0x30,
0x03, 0x08, 0x28,
0x01, 0x03, 0x20,
0x03, 0x10, 0x10,
0x03, 0x08, 0x08,
0x01, 0x02, 0x00
ArrayT of
Octet-
StringT3
0x01
Flow value MDC1
0x03, 0x10, 0x30
Octet-
StringT3
0x02
Flow scale MDC1
0x03, 0x08, 0x28
0x03
Flow monitoring
SSC1.1 (OutA), SSC1.2
(OutB),Volume / mass
pulse SSC1.3 (OutC,
Puls)
0x01, 0x03, 0x20
0x04
Temperture value
MDC2
0x03, 0x10, 0x10
0x05
Tempertaure scale
MDC2
0x03, 0x08, 0x08
0x06
Temperature moni-
toring SSC2.1, SSC2.2
0x01, 0x02, 0x00
0x003A
(58)
0x00
R/W
Teach Channel
0: SSC1.1 (OutA)
1: SSC1.1 (OutA), fac-
tory setting
2: SSC1.2 (OutB)
11: SSC2.1
12: SSC2.2
UInte-
gerT8