HSP-...-AP/A S
Festo HSP-...-AP/AS 2017-10b English
25
Replacing the rubber buffers in the fixed stops (HSP-...-AS):
1. Switch off the power supply of the drive.
2. Remove the protective cover.
3. Use a suitable tool to remove the rubber buffer of the fixed stop (e.g. screwdri
ver, pliers).
4. Press the new rubber buffer into the fixed stop.
5. Fasten the protective cover.
Fig. 25