HSP-...-AP/A S
Festo HSP-...-AP/AS 2017-10b English
18
Please note
For the type HSP-...-...WR/WL: Please observe the warnings and instructions in
the operating instruction for the BWR-/BWL-HSP-...
S
Pressurize the add-on components. If necessary, carry out a separate test run
to check that the add-on components are functioning correctly.
Add-on components
Tests
Without work load
– Correct assignment of the compressed air
connections
– Gripping speed
– Function of the proximity switches
With work load
– Reliable holding of the work load
S
Pressurize the drive in one of the following ways as desired:
–
slow
pressurization of one side
– simultaneous pressurization of both sides with subsequent exhausting of
one side.
Please note
Swivel module DSM-... for HSP-...-AP may only be commissioned in unmodified
state as at delivery and with protective cap.
Please note
S
Start first of all a test run at reduced operating speed.
S
Accelerate in steps until the operating speed is reached. For this speed,
please refer to the calculations for your application.
S
Interrupt the test run if:
‒ there is a metallic knocking of the stop screws
‒ the double rollers do not run smoothly in the path guide
‒ the end positions are not reached
‒ the work load falls down.
For eliminating faults, please refer to the information in chapter 12.